Pins
1 = Shield
4
3
2 = +In
5
3 = GND
4 = CAN H
1
2
5 = CAN L
Short-circuit resistance:
Reverse polarity protection:
Overvoltage protection:
Insulation voltage:
Construction material
Non-wetted parts:
Wetted parts:
Installation guidance
The sealing faces at the instrument have to be undamaged and clean.
When screwing the instrument in, the force required to do this must not be applied through the casing, but only through the
spanner flats provided for this purpose and using a suitable tool.
The correct torque depends on the dimensions of the process connection and the gasket used (form/material).
When screwing in, do not cross the threads.
Maximum tightening torque = 27Nm
Maintenance
This instrument is maintenance-free.
Repairs must only be carried out by the manufacturer.
CAN-High/CAN-Low vs. +In/GND
+Vin vs. GND
36 Vdc
500 Vdc
Stainless Steel
Stainless Steel
Sealing materials