INSTRUCTIONS TO CODIFY RELAY ART.170D
The relay enables the activation of S!, S2 and S3 outputs simply digiting 4 or 8 digit number from a Digibus entrance panel (942,
946) either by means of the standard procedure (number + C) or by pressing one of the interphone function push-buttons.
The standard application enables the door lock release using 3 different codes and 3 different activation times when the device is
connected to timers with programmed output.
The 3 outputs may be programmed at different activation times for particular applications. The procedure to program the code and
the activation time is the following:
1) Press PROGR. push-button inside the relay Art. 170D and keeping it pressed, press also SHIFT push-button, release PROGR.
and then SHIFT. The diode LED S1 ON shows that you can enter the programming of the corresponding output S1.
2) By pressing SHIFT push-button several times in series the output programming changes (diode LED S1, S2, S3 switch on se-
quentially).
3) Select a 4 or 8 digit number from the entrance panel or the interphone function push-buttons using the standard procedure (num-
ber + C) or the secret procedure (R1 + number or 0 + number or C + number related to the panel programming).
4) The LED which was ON, switches off for a while showing that the code has entered.
5) Introduce the standard activation time by pressing 1 + C (for particular applications you can introduce activation times from 0001
to 9999).
6) The LED ON definitively switches off to show that the code has entered and that the programming is over.
7) The programming of the other outputs is carried out repeating the procedure from 1 to 6.
A jumper has been inserted between pins 6 and 7 of the additional connector CN2: with the jumper iserted the operation remains
the basic one while cutting it, the 3 outputs are enables by means of the function push-buttons of the interphone and not through
the panel.
Each output may be programmed by digiting a number on the entrance panel or interphone. In the latter case the device will ena-
ble the programmed output only if it will receive the interphone number and the respective command.
In both cases the activation time must be programmed from a numerical entrance panel.
Number
4 or 8 digit code and respective command
(according to the type of panel/interphone)
For example:
S1: output activated by command from entrance panel and number 123
S2: output activated by command F1 from interphone number 12345678
S3: output activated by command F6 from interphone number 12345678
Operation with JUMPER 6 - 7 CUT
Outputs S1, S2 and S3 are activated by any of the interphone function push-buttons without distinguishing the particular inter-
phone number. Programming is to be made in an analog way as the previous procedure: the command is sent by an interphone,
whilst the activation time by a numerical entrance panel.
Commands possible from the interphone
DOOR LOCK RELEASE/ INTERPHONE CALL
F1/F2/F3/F4/F5/F6/F7/F8
For example
S1: output activated by command F6 from EACH interphone
S2: output activated by command LOCK RELEASE from EACH interphone
S3: output activated by command F2 from EACH interphone.
Operation with JUMPER 2 - 5 CUT:
Cutting jumper 2 - 5 and pressing push-button R on entrance panel all the outputs are DEACTIVATED at any moment without ta-
king into consideration the activation time previously programmed.
With jumper inserted, the device is not influenced if you press R push-button.
Command from entrance panel
R
Programming is necessary even if the device receives the commands only from the interphone. In this case the code entered in point
3 may be any, provided it is according to the type of interphone (4 or 8 digits).
From relay type 170D it is possible to communicate with the external entrance panel by inserting an handset accessory, supplied
as an option, connected to connector CN1.
170D
Operation with JUMPER 6-7 INSERTED
JUMPER 6 - 7 INSERTED
JUMPER 6 - 7 CUT
JUMPER 2 - 5 CUT
3/12
Enabled output
S1/S2/S3
(according to the programmed code)
Activated output
S1/S2/S3
(according to the programmed code)
Deactivated output
ALL
GB