oPeRATIoN
Continued
CAUTION: Do not try to ad-
just heating levels by using the
equipment shutoff valve.
TO TURN OFF GAS
TO APPLIANCE
1. Turn control knob clockwise
OFF position.
2. Turn off all electric power to the appliance
if service is to be performed.
3. Close equipment shutoff valve (see Figure
16, page 14).
THERMOSTAT CONTROL
OPERATION
The thermostatic control used on these
models differs from standard thermostats.
Standard thermostats simply turn on and off
the burner. The thermostat used on this heater
senses the room temperature. The thermostat
adjusts the amount of gas flow to the burner.
This increases or decreases the burner flame
height. At times the room may exceed the
set temperature. If so, the burner will shut
off. The burner will cycle back on when room
temperature drops below the set temperature.
The control knob can be set to any heat level
between 1 and 5. Selecting the 5 setting will
cause the burner to remain fully on without
modulating down in most cases.
16
Note: The thermostat sensing bulb mea-
sures the temperature of air near the heater
cabinet. This may not always agree with
room temperature (depending on housing
construction, installation location, room size,
open air temperatures, etc.). Frequent use of
your heater will let you determine your own
comfort levels.
to the
1. Remove front panel (see Figure 7, page 9).
2. Follow steps 1 through 7 under Lighting
Instructions, page 15.
3. With control knob pressed in, strike match.
Hold match to pilot until pilot lights.
4. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob. Now follow step 9,
under Lighting Instructions, page 15.
5. Replace front panel.
www.desatech.com
MANUAL LIGHTING
PROCEDURE
121254-01A