EN
If the temperature detected by food temperature prove does not reach cycle set point, when maximum
cycle duration time has been reached, the cycle will continue till the set temperature is reached. Then,
TEMPERATURE CONTROLLED CYCLE
will light up and buzzer will be active. Press any button to mute the buzzer.
Finally, once the cycle process ending is indicated, if the chilling has bee successful, the device goes
on conservation mode lightning up CONSERVATION
TEMPERATURE CONTROLLED CYCLE
ALARM (6, Fig.5) icon will lifht up. While this status last, compartment temperature will be displayed
on the screen.
In addition, during conservation, if the process has been succesfull, the elapse between real cycle
time and default maxium cycle duration time can be checked. Whereas, if the process failed, the elapse
of time between the maxium cycle duration and the instant when the food temperature probe detects
the set point can be displayed. For both cases, press DOWN (12, Fig.5) button. Press DOWN DOWN
(12, Fig.5) button, once again so as to display chamber temperature and press SET
Fig.5), button to exit the application.
To interrupt chilling process in any of its state, press START/STOP
seconds.
5.1.2.3
Start a cycle with the same program as the last cycle started
Make sure that the keyboard is not locked. Press SET
type of cycle will be displayed. Press SET (14, Fig.5) button in the following 15 seconds.
Temperature probe insertion verification test
Set-temperature cycles are preceded by a test step in order to check correct pin probe insertion.
The test has two stages:
The outcome of the first stage is positive if "the temperature measured by the pin probe - the temperature
of the cabinet" is greater than the value set by parameter rc at least 3 times out of 5 (the comparison is made
every 10 s), if parameter rc is set to 0, neither the first nor second stages will be run.
If the outcome of the first stage is positive, the second will not be run
If the outcome of the first stage is negative, the second will be run. The outcome of the second stage is
positive if the difference "temperature measured by the pin probe - temperature of the cabinet" is greater by
at least 1ºC/1ºF (with respect to the previous comparison) at least 6 times out of 8 (the comparison is made
every "rd/8 s").
If the outcome of the test is positive, the cycle will be activated.
If the outcome of the test isn't positive, the cycle will be started in timed mode and icon
If power is interrupted during the test, when power is restored, the test will start again from the beginning.
Operational state
"ON" STATUS
The device is switched on but operating cycle is running, If power is interrupted:
During a timed blast chilling operation, when power is restored, chilling will continue from the time point at
which the interruption occurred (with a maximum error of 10 minutes);
During a set-temperature blast chilling operation, when power is restored, chilling will start again from the
beginning;
During a storage operation, when power is restored the storage operation will be reset.
"STAND-BY" STATUS
The device is switched on but no operating cycle is running. If power is interrupted while in "stand-by" mode,
when power is restored the device will be in the same state.
Defrosting
The blast chiller you have adquired only has a manual defrost process. The food that is introduced into
the appliance, as well as the opening of doors, generate humidity inside the machine. When performing
a blast chilling cycle, this moisture condenses and freezes at the coldest point of the blast chiller, which
is the evaporator, accumulating ice. In some cases, this accumulation might cause evaporator blocking
(2, Fig.5). icon will blink and ALARM
(7, Fig.5) icon together with
(2, Fig.5). On the oppsite, if the cycle has failed,
(14, Fig.5) button. Last carried out
24
(6, Fig.5)
(14,
(13, Fig. 5), button for 2
(2, Fig.5)