ASBER BC-GN 03 Instrucciones De Instalación, Uso Y Mantenimiento página 23

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1
EN
o
o
o
4.
Press START/STOP
Fig.5) will light up.
During the chilling process, the DISPLAY will show remaning cycle time. When the cycle time is over,
the DISPLAY will show the word "END" and the buzzer will be activated during the time specified on
"AA" parameter. To mute the buzzer press any icon.
Finally, once process finishing is indicated, conservation process is activated lightning up
CONSERVATION
Additionally, during chilling cycle, it is possible to show the chamber temperature in the display. Press
DOWN button (12, Fig.5), choose the chilling option which is in force "PoS" for refrigeration or "nEG"
for frezzer. Once the cycle is choosen, press again DOWN button (12, Fig.5) to show this value. To
exit the process, press SET button (14, Fig.5) or do not take any further action for the following 15
seconds.
In order to interrupt a chilling process, press START/STOP
5.1.2.2
Temperature controlled chilling cycle
To run a time controlled blast chilling cycle follow these steps:
1.
Make sure that the keyboard is not locked and that no chill or defrost cycle is active.
2.
Press SET
freezing chilling process"nEG" and ensure that the
Fig.5) blinks. By default, food temperature probe set point for refrigeration cycle is set in 3°C, while for
freezing cycle is defined in -18°C.
3.
Before a temperature controlled cycle starts, an automatic test is carried out, in order to check that the
temperature sensor is correctly inserted into the food to be chilled. If test fails, corresponding time
controlled cycle starts.
4.
OPTIONAL: Parameters related with the temperature probe value at the end of chilling cycle, maximum
cycle duration time, chamber setpoint during chilling cycle and chamber setpoint on conservation cycle
can be adjutasted.
o
o
o
o
o
5.
Press START/STOP
Fig.5) will light up.
If the temperature detected by food temperature probe reaches cycle set point, before maximum
duration time has been reached, "EnD" word will be displayed on the screed, buzzer will be activated
during the period established on "AA" parameter and the devices will go on conservation mode. Press
any button to mute the buzzer and press again another button to remove "EnD" indicator.
To check and modify the set point of the chilling process, press DOWN button (12, Fig.5), before
15 seconds and press SET (14, Fig.5). In order to change the value press UP
Fig.5) or DOWN (12, Fig.5). Press again SET button (14, Fig.5) to exit and continue to the
next step.
To check and modify the set point of the conservation cycle, press DOWN button (12, Fig.5),
before 15 seconds and press SET (14, Fig.5). In order to change the value press UP
(11, Fig.5) or DOWN (12, Fig.5). Press again SET button (14, Fig.5) to exit and continue to
the next step.
This is a temporary adjustment. When activating a new cycle or when a power failure occurs,
these values are reset to those defined by the manufacturer.
(13, Fig. 5), the cycle will run and
(7, Fig.5) icon and chamber temperature is shown in the DISPLAY.
button (14, Fig.5) to choose between a refrigeration chilling process "PoS" or
Press button DOWN
to check the product final temperature value and modify it. The value can be changed by
pressing UP
(11, Fig.5) or DOWN
back to previous level.
In order to watch and modify chilling cycle maximum duration press DOWN (12, Fig.5), button
again in a period not exceeding 15 seconds and press SET (14, Fig.5) button again. Press UP
(11, Fig.5) or DOWN (12, Fig.5) buttons to change the value. Press SET (14, Fig.5) to come
back to previous level.
In order to watch and modify chamber temperature set point during chilling process press
DOWN (12, Fig.5), button again in a period not exceeding 15 seconds and press SET button
again. Press UP (11, Fig.5) or DOWN (12, Fig.5) buttons to change the value. Press SET (14,
Fig.5 to come back to previous level.
In order to watch and modify the set point during conservation process press DOWN (12,
Fig.5), button again in a period not exceeding 15 seconds and press SET (14, Fig.5) button
again. Press UP (11, Fig.5) or DOWN (12, Fig.5) buttons to change the value. Press SET (14,
Fig.5 to come back to previous level.
This is a temporary adjustment. When activating a new cycle or when a power failure occurs,
these values are reset to those defined by the manufacturer.
(13, Fig. 5), the cycle will run and
TIME CONTROLLED CYCLE
(13, Fig. 5), for 2 seconds
TEMPERATURE CONTROLLED CYCLE
(12, Fig.5), before 15 seconds and press button SET (14, Fig.5)
(12, Fig.5) buttons. Press SET to come
TIME CONTROLLED CYCLE
23
(11,
icon (10,
.