Technical Data; Electrical Data; Operating Conditions; Temperature - DAB KC Serie Instrucciones Para La Instalación Y El Mantenimiento

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 39

3. TECHNICAL DATA

3.1 Electrical data

Supply voltage:
Absorbed power:
Maximum current:
Protection rating:

3.2 Operating conditions

Flow rate:
Head:
MODEL
KC - KCV 100
KC/KCE - KCV/KCVE 150
KC/KCE - KCV/KCVE 200
KC/KCE - KCV/KCVE 250
KCV/KCVE 300
Maximum working pressure:
Motor construction:
Noise production:
MODEL
KC - KCV 100
KC/KCE - KCV/KCVE 150
KC/KCE - KCV/KCVE 200
KC/KCE - KCV/KCVE 250
KCV/KCVE 300

3.3 Temperature

Environment temperature:
Storage temperature:
Liquid temperature:

4. MANAGEMENT

4.1 Storage

All the pumps must be stored in a dry covered place,
with possible constant air humidity, free from
vibrations and dust.
They are supplied in their original pack in which they
must remain until the time of installation.
If this is not the case, accurately close the suction and
delivery mouth.

4.2 Transport

Avoid subjecting the products to needless impacts
and collisions. To lift and transport the pump use
lifting devices with the aid of the pallet supplied with it
(if contemplated).

4.3 Weight

The adhesive plate on the packaging indicates the
total weight of the pump.
1 x 220-240 V 50Hz
1 x 220-230 V 60Hz
3 x 230-400 V 50Hz
3 x 220-277/380-480 60Hz
see electrical data plate
see electrical data plate
IP54
Page 50
see table
Head
H max (m)
10.5 m
13 m
16 m
22 m
23 m
6.5 bar
CEI 2-3 – CEI 61-69
(EN 60335-2-41)
Noise
Level
≤ 59 dB (A)
≤ 59 dB (A)
≤ 59 dB (A)
≤ 62 dB (A)
≤ 62 dB (A)
-20 ÷ +65℃
-20 ÷ +50℃
(only single-phase versions)
-40 ÷ +65℃
-10 ÷ +55℃
ENGLISH

5 INSTALLATION

5.1 Pump installation

The pump must be installed in a horizontal position
with the suction manifold as short as possible and
with minimum suction height.
The pump must be installed in a well ventilated
place,
protected
conditions, and with an environment temperature
not higher than 65°C (50°C for single-phase
versions).
The pump may be installed outdoors, but it must be
protected against atmospheric agents with a
suitable cover.

5.2 Pipes

Interception valves must be fitted upstream and
downstream from the pump.
The pump must not be subject to mechanical
stresses by the pipes.
The pipes must be correctly sized, also taking the
suction pressure into account.
If the pump is installed in the lowest point of the
system, residue and impurities may build up inside
it.
Install the pump so as to avoid air pockets,
especially on the suction side of the pump.
Fig. 1

5.3 Connecting the pipes

5.3.1 Suction pipe

If the pump is installed above the level of the liquid,
a foot valve or non return valve must be installed in
the suction manifold below the level of the liquid.
Connect the suction pipe to the suction mouth of
the pump. (Fig. 2).
Each coupling of the suction manifold must be well
tightened and completely watertight.
If a hose is used as the suction pipe, it must be of a
non collapsible type. It is recommended to use a
grid or filter if there is a possibility of solids getting
into the suction pipe and blocking the pump.
16
from
unfavourable
weather