Master GEO Manual De Uso Y Mantenimiento página 15

Motores tubulares 45 mm y 35mm con final de carrera electronico
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

09. EARLY STOP
This function is available only if the upper limit switch has been learned by pressure.
It is possible to define whether the motor must always reach the phisical stop or it must stop before and only after 30
complete upward manoeuvres reach the phisical stop.
The factory sets this parameter to 1 (always in phisical stop).
To change this parameter follow the this procedure.
WARNING:
During the execution of points 03 to 07 always keep the UP button
01. Bring the motor in a intermediate position.
02. Press together UP and DOWN for 1 second, then release DOWN (keeping pressed UP)
03. (Keep pressing UP) wait 3 seconds.
04. (Keep pressing UP) press briefly and quickly 5 times DOWN.
05. (Keep pressing UP) wait. Motor signals the current setting (from 1 to 9 movements, see table).
06. (Keep pressing UP) press briefly and quickly from 1 to 9 times DOWN.
07. (Keep pressing UP) wait. Motor signals the new setting (from 1 to 9 movements, see table).
10. CLOSE PRESSURE
This function is only available if the upper limit switch has been learned by pressure.
If the upper limit switch has been learned by pressure (eg awning with cassette), it is possible to select the pressure with
which the cassette closes.
The factory sets this parameter to the value 3 (average pressure).
To change this parameter follow this procedure.
WARNING:
During the execution of points 03 to 06 always keep the UP button
01. Bring the motor in a intermediate position.
02. Press together UP and DOWN for 1 second, then release DOWN (keeping pressed UP)
03. (Keep pressing UP) wait 3 seconds.
04. (Keep pressing UP) press briefly and quickly 7 times DOWN.
05. (Keep pressing UP) wait. Motor signals the current setting (from 1 to 4 movements, see table).
06. (Keep pressing UP) press briefly and quickly from 1 to 4 times DOWN.
07. (Keep pressing UP) wait. Motor signals the new setting (from 1 to 4 movements, see table).
11. RESET
WARNING:
During the execution of points 02 to 06 always keep the UP button
01. If possible bring the motor in a intermediate position.
02. Press together UP and DOWN for 1 second, then release DOWN (keeping pressed UP)
03. (Keep pressing UP) wait 3 seconds.
04. (Keep pressing UP) press briefly and quickly 9 times DOWN.
05. (Keep pressing UP) wait 3 seconds.
06. (Keep pressing UP) press the DOWN button until the motor signals UP-DOWN (about 2 seconds), then release the buttons.
07. Reset done.
NOTE:
the same procedure can be performed by inverting the UP and DOWN buttons
Disposal
MASTER uses packaging recyclable materials. Dispose materials on the proper containers, complying with the law in force in your locality.
This product may have substances that are polluting for the environment and dangerous for the health.
At the end of the product life cycle, carefully comply with the waste disposal rules. It is strictly forbidden to dispose the product on the domestic waste.
All products and technical specifications given in this document are subject to variation without notice. Unless previously and specifically authorised by the manufacturer, the device must be used exclusively with
transmitters produced by the same manufacturer. The manufacturer shall not be liable for damage resulting from improper, incorrect or unreasonable use.
R
All rights reserved.
07
N° of movements
*
No (always phisical stop)
1
2
Near phisical stop
3
....
Far from phisical stop
9
*factory setting
N° of movements
Close pressure
1
2
*
3
4
*factory setting
Early stop
Maximum
++
+
Minimum
Tabla de contenido
loading

Este manual también es adecuado para:

Side

Tabla de contenido