5-2 Dialing code indication mark
See Tab.5.2 and Tab.5.3.
Tab 5 2 Dialing code
SN
Definition
The night time silent
SW4
mode selection
Static Pressure set
SW5
selection
Start time set and
SW7
anti-snow function
Night
silent
and
SW8
address
setting function
SW9
Mode selection
1
. .
Legend
Function
SW4
The night time isselected as 6h/10h
ON DP
(factory default)
1 2 3
SW4
ON DP
The night time is selected as 8h/10h
1 2 3
SW4
ON DP
The night time is selected as 6h/12h
1 2 3
SW4
ON DP
The night time is selected as 8h/8h
1 2 3
SW5
Standard static pressure
ON DP
(factory default)
1 2 3
SW5
ON DP
Low static pressure
1 2 3
SW5
ON DP
Middle static pressure
1 2 3
SW5
ON DP
High static pressure
1 2 3
SW5
ON DP
Super static pressure
1 2 3
SW5
ON DP
Silence
1 2 3
SW5
ON DP
High silence
1 2 3
SW5
ON DP
Super-silence
1 2 3
SW7
The start time is set as 12 minutes,
ON
without anti-snow function
(factory default)
1 2
SW7
The start time is set as 7 minutes,
ON
without anti-snow function
1 2
SW7
The start time is set as 12 minutes,
ON
with anti-snow function
1 2
SW7
The start time is set as 7minutes,
ON
with anti-snow function
1 2
SW8
Night silent mode and
ON DP
automatic addressing
1 2 3
(factory default)
SW8
ON DP
Night silent mode and non
automatic addressing
1 2 3
SW8
ON DP
Reserved
1 2 3
SW8
ON DP
Non night silent mode and
automatic addressing
1 2 3
SW8
Non night silent mode and non
ON DP
automatic addressing
1 2 3
SW9
First start priority
ON DP
(factory default)
1 2 3
SW9
ON DP
Heating priority
1 2 3
SW9
ON DP
Cooling priority
1 2 3
Continue Tab.5.2
SN
Definition
SW9
Mode selection
SW12
Power check
function
SW13
Fan motor selection
SW6 Outdoor address setting
3 4 5
3 4 5
2
6
2
1
7
1
0
8
0
F
9
F
E
A
E
D
B
C
0
Master
Slave 1
SW11 Outdoor capacity setting
3 4 5
3 4 5
2
6
2
1
7
1
0
8
0
F
9
F
E
A
E
D
B
C
0
8HP
10HP
3 4 5
3 4 5
2
2
6
1
1
7
0
8
0
F
F
9
E
E
A
D
B
C
4
16HP
18HP
3 4 5
3 4 5
2
2
6
1
1
7
0
8
0
F
F
9
E
A
E
D
B
D
C
8
24HP
26HP
3 4 5
2
6
1
7
0
8
F
9
E
A
D
B
C
C
32HP
Reserved
Remark: Dialing operation cannot be performed unless the power supply
is cut off.
13
Legend
Function
SW9
ON DP
Heating only
1 2 3
SW9
ON DP
Cooling only
1 2 3
SW9
VIP No.63 address
ON DP
&Automatic priority
1 2 3
SW12
ON
Reserved
1 2
SW12
ON
Reserved
1 2
SW13
ON
Reserved
1 2
SW13
ON
Reserved
1 2
. .
Tab 5 3 Dialing code 2
3 4 5
2
6
6
1
7
7
0
8
8
F
9
9
E
A
A
D
B
D
B
C
C
1
2
Slave 2
3 4 5
2
6
6
1
7
7
0
8
8
F
9
9
E
A
A
D
B
D
B
C
C
1
2
12HP
3 4 5
2
6
6
1
7
7
8
0
8
F
9
9
A
E
A
D
B
D
B
C
C
6
5
20HP
3 4 5
2
6
6
1
7
7
8
0
8
F
9
9
A
E
A
B
D
B
C
C
9
A
28HP
E
D
Reserved
3 4 5
2
6
1
7
0
8
F
9
E
A
D
B
C
3
Slave 3
3 4 5
2
6
1
7
0
8
F
9
E
A
D
B
C
3
14HP
3 4 5
2
6
1
7
0
8
F
9
E
A
D
B
C
7
22HP
3 4 5
2
6
1
7
0
8
F
9
E
A
D
B
C
B
30HP
F
Reserved
V.1
V.1