6) DISPLAY OUTPUT
Select the display resolution you want. There are four options as follows:
AUTO (default)
Note: To have the best image quality on your monitor, make sure (1) the selected DVR output
resolution is supported by your monitor, and (2) the output settings on both the LCD monitor and
DVR are consistent. If the image is not positioned or scaled properly, please go to your monitor's
menu for adjustment. For details, please refer to the user manual of your monitor.
7) COVERT UNLOCK IN SUPERVISOR MODE
Enable this function to allow the supervisor user to see live view even when the channel is set "COV." to "ON"
in "ADVANCED CONFIG" "CAMERA".
5.4.7 RECORD
Note: Please DO NOT change the date or time of your recorder after the recording function is activated.
Otherwise, the recorded data will be disordered and you will not be able to find the recorded file
to backup by time search. If users change the date or time accidentally when the recording
function is activated, it's recommended to clear all hard disk data, and start recording again.
CONNECTION
CAMERA
DETECTION
ALERT
NETWORK
DISPLAY
RECORD
NOTIFY
PSE
MULTICASTING
EXIT
1) MANUAL RECORD
Set the manual recording function on / off.
2) EVENT RECORD
Set the event recording function on / off.
3) TIMER RECORD
Set the timer recording function on / off.
4) PRE-ALARM RECORD
Select to enable or disable the pre-alarm function (ON / OFF).
When pre-alarm and event recording functions are both activated, the recorder will record 8MB data before
an alarm / motion event is triggered.
5) OVERWRITE
Select "ON" to overwrite previous recorded data in your HDD when the HDD is full. When this function is on
and the HDD is full, the recorder will clear 8GB data from the oldest for continuous recording without notice.
6) KEEP DATA LIMITS (DAYS)
Assign the maximum recording days from 01 to 31 after which all the recorded data will be removed, or
select "OFF" to disable this function.
7) RECORD CONFIG
Click "SETUP" to enter the setting page individually for manual record, event record and timer record.
For details, please refer to "5.1.1 GENERAL" at page 19.
1920 x 1080
ADVANCED CONFIG
MANUAL RECORD
EVENT RECORD
TIMER RECORD
PRE-ALARM RECORD
OVERWRITE
KEEP DATA LIMIT (DAYS)
RECORD CONFIG
1280 x 720
OFF
ON
OFF
ON
ON
OFF
SETUP
36
MAIN MENU
1024 x 768