5.2 Connection of the power cord
1.A power cord is connected to the outside of chamber
(1) Remove the front side or the large handle from an outdoor unit.
(2) Connect the wires correspondingly to the "L", "N", and ground terminals or "L1", "L2", "L3", "N" and
ground terminals.
(3) Tie the wires and fixed it using a press clamp
2.Connect the power cord in the room
(1) Remove the indoor distribution box.
(2) Connect the wires correspondingly to the "L", "N", and ground terminals or "L1", "L2", "L3" and
ground terminals.
(3)Tie the power cord and fixed it using a press clamp
5.3 Line controller 9 : Cable connection
(1) Open the electrical appliances box cover on the indoor unit.
(2) Passing signal line of line controller through the rubber ring.
(3) Insert the signal wire of line controller into five needle seat on the electronic control panel of the
indoor unit.
!
Notice
Special attention must be paid when perform wiring operations, to avoid air conditioner malfunction due to
electromagnetic interference.
(1) The signal line shall be separated from the power supply line and outdoor and indoor connection line;
(2) If the air conditioner is installed in a place susceptible to interference, it's best to use shielded wire
and twisted pair as the signal line of wired remote control
5.4 Installation of connecting cables for indoor unit and outdoor unit
Communication cables for indoor unit and outdoor unit must be connected in strict accordance with the
identification. L1, N1, S, ground terminal of the indoor unit and L1, N1, S, ground terminal of the outdoor unit
must be connected correspondingly, do not connect wrong.
5.5 Unit wiring diagram
Connections for a variety of indoor and outdoor models, see "Wiring diagram".
Note: The following drawings are for reference only, when comparing, the wiring nameplate will prevail.
5 Electrical Installation
.
26