Indicator Light - AKO BA-1087 Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 7
Specific Operating Instructions
1
2
5
6
3
Possible current sources:
-12 Volt
Not suited for use in barns!
Do not connect to operating equipment with a mains connection.
a.) Functional description of the energizer
Open the appliance by opening the closing cap on both sides. Operate the appliance only in vertical position
and with closed lid, see above picture!
b.) Functional description of the unit
Put unit into service WITHOUT fence and earthing. When connecting the 12V accumulator, be sure to
observe the correct polarities (red + and black -). If the fence light (1) flashes green, the unit is ready for use. If
in addition the accumulator light (2) flashes red, check the 12V accumulator for correct voltage. If the fence
light (1) does not flash, check the polarity of the 12V connecting cable on the accumulator or have the unit
checked by a technician.
c.) Functional description with connected fence system ( fence + earth )
Accumulator
Fence light
light (2)
(1) flashes
flashes red
1
NO
2
NO
YES
3
YES
4
YES
5
6
NO
If the fence light (1) flashes faster than approx. once per second, the unit must be disconnected at once and
checked by a technician before it can be used again.
For increased running time, a number of Solar modules with support stands can be used. We recommend the
use of a wet accumulator at 12V-85Ah. The accessories for this unit are obtainable through specialized
dealers!
!!!Attention: Earth electrodes are not included in the supply (use at least 3 earth electrodes approx. 1m long) !!!
This equipment carries a 3-year warranty in accordance with our Warranty Terms & Conditions!
Please see the attached Operating Instructions for safety tips, earthing, commissioning, maintenance
of battery and accumulator, warranty terms and conditions and potential sources of fault!
SERVICE Addresses:
Please contact your specialist dealer
Audible
clicks
green
YES
YES
YES
NO
YES
YES
YES
NO
NO
NO
NO
NO
4
Output voltage
> 3500 V = minimum requirement
< 3500 V; see fault finding in the enclosed
instruction manual (Figure 2, p.5)!
> 3500 V = minimum requirement
and:
< 3500 V; see fault finding in the enclosed
instruction manual (Figure 2, p.5)!
No pulses, deep charge protection activated
See b.) Functional description of the appliance, without fence and earth
3
Fence voltage
1

Indicator light

12V-ACCUMULATOR
2
indicator light
3 switch
12V battery connection
4
cable
5 Earth connection
6 Fence connection
12V accumulator
OK ( >12,2V)
OK (>12,2V)
Charge or replace as
soon as possible
Charge or replace as
and:
soon as possible
Charge or replace at
once
-EN-