Controls & Functions - Work Pro W DMXnet 8 Manual De Uso

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

EN
Controls & Functions:
1
2
5 6
7
1. Power LED: This LED in red color, will iluminate when there is power currently being
supplied to the unit.
2. LINK LED: This yellow LED in on when the Ethernet LAN port is connected to the network.
3. DATA LED: This green LED blinks when the Ethernet port is transmitting the data.
4. DMX 1-8 LEDs: This blue LEDs blinks when the output is working fine. In the LEDs are ON,
the output disable.
5. Subnet selector: In ArtNet, dispswitch 0-F allow to select the Subnet, with the value from 0
to F (16 positions)
6. UNIV selector: Allows to select one of the 16 DMX universes in the configured Subnet.
7. LAN: RJ 45 connector which allows to connect to the network.
8. DMX Outputs: These XLR connectors send the converted DMX signal to a control line with
compatible DMX devices like moving heads, scanners, RGB drivers, etc.
9. Fuse: F3.15A, 250V, 50/60 Hz
10. Power input: AC 96-264 V 50/60 Hz.
11. Power Switch: This is the main power switch and turns power on and off.
Universe setup:
- Select with the switch (5), the Subnet.
- Select the first universe with the switch (6). This universe will be output 1 and, the following
universe will be output 2 and sucessively.
3
8
DMXnet 8
4
- 2 -
FRONT
SIDE
REAR
SIDE
9
10
11
User Manual/Manual de Uso