Actuador vía radio 2 canales
Timer behaviour, voltage re
turn
Switchoff warning
Priority, lockout protection
Priority, restraint
Priority, wind alarm
Priority, sun protection
Priority, twilight
Switchoff on brightness
overshoot
82579113
J:0082579113
Off
Restart
Basic setting: Off
On, Off
Basic setting: Off
0...4
Basic setting: 1
0...4
Basic setting: 2
0...4
Basic setting: 3
0...4
Basic setting: 0
0...4
Basic setting: 0
On, Off
Basic setting: On
9/11
Specifies whether the timers
for switchon delay, switchoff
delay and runon time remain
off after voltage return or
whether they restart. Directly
connected to the parameters
"Switchon delay", "Switchoff
delay" and "Runon time".
If the switchoff warning is ac
tive, the light is not switched
off directly. The light goes off
30, 15 and 6 seconds before
permanent switchoff. During
the switchoff warning, a
switchon telegram effects di
rect switchon. It is not possi
ble to terminate the time using
a switchoff telegram.
Specifies the priority for reca
lling and removing a scene of
type Lockout protection for
the channel.
Specifies the priority for reca
lling and removing a scene of
type Forced position for the
channel.
Specifies the priority for reca
lling and removing a scene of
type Wind alarm for the chan
nel.
Specifies the priority for reca
lling and removing a scene of
type Sun protection for the
channel.
Specifies the priority for reca
lling and removing a scene of
type Twilight for the channel.
Allows automatic switchoff
according to the brightness. If
the parameter is On, then the
light controller switches off au
tomatically when the bright
ness setpoint is greatly excee
ded. This parameter is not yet
active, as a light controller has
not yet been implemented.