Jung FM AS 26 UP Instrucciones De Servicio página 7

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

eNet
Actuador vía radio 2 canales
Operating mode
Local Operation
Manual switch­off of the run­
on time
82579113
J:0082579113
Switching
Buttons
Flashing
Continuous on
Continuous off
Basic setting: Switching
On, Off
Basic setting: On
On, Off
Basic setting: Off
7/11
Switching
After switch­on, the device re­
mains stable in the "On" state,
and stable in the "Off" state af­
ter switch­off.
Buttons
The device switches "On"
when any channel button of a
radio transmitter is pressed
and "Off" when the button is
released. It is irrelevant whet­
her the "On" or "Off" channel
button is pressed.
Flashing
Switch­on starts flashing and
switch­off stops flashing. The
default flash frequency is 1
Hz. This frequency is also the
maximum flash frequency.
The flash frequency can be
changed using parameters.
The parameter "Switch­off de­
lay" is used for the pulse time
and the parameter "Switch­on
delay" for the pause time.
Continuous on
The output switches to conti­
nuously "On". All operations of
radio transmitters and the
Prog button are ignored.
Continuous off
The output switches to conti­
nuously "Off". All operations of
radio transmitters and the
Prog button are ignored.
Blocks the output for operation
using the Prog button.
Allows manual switch­off of a
running run­on time. If the pa­
rameter is switched off, then a
switch­off command will also
switch the actuator on. This
parameter is directly connec­
ted to the "Run­on time" para­
meter.
12.03.2014
Tabla de contenido
loading

Tabla de contenido