PUTTING INTO OPERATION

Before putting the plug in the socket let it stay still for about an hour. In case the trans-
port has been done with the unit laid down, it is advisable to wait for 24 hours.
Check that the actual network voltage corresponds to the one stated on the technical
data plate . Do not lay anything on the cabinet (plants, boxes, etc..)and leave a free
space of minimum 50 cm. over the cabinet.
The electric line where the unit will be connected must be protected by any high
sensitivity differential switch (In=16A,Id=30mA) and connected to general earthing.
The refrigerator must be installed on a power line/outlet provided with suitable
protection and connected to the main earth circuit as per regulations (e.g. via a high
sensitivity breaker, In = 16 A , Id = 30 mA).
THE EARTHING OF THE INSTALLATION IS A SAFETY STANDARD WHICH IS
ENFORCED BY LAW.OUR COMPANY HAS PROVIDED FOR THIS CONNECTION
ACCORDING TO THE EXISTING STANDARDS AND THEREFORE WE DECLINE ANY
RESPONSABILITY FOR POSSIBLE DAMAGES TO PEOPLE OR THINGS.
Under no circumstances connect the unit using adapters, multi-point sockets or
extension cables, and make sure that the capacity of the electrical system and power
outlets comply with regulations and are suitable for the rated power of the unit
indicated on the plate. If in doubt, and for periodic verification of the safety of the
electrical
system
and
connected
units,
refer
to
qualified
personnel.
After plugging make run the cabinet for about 2 hours with the light off and empty.
Then load the products:
do not place the products over the shelves edges, because over the frontal edge the
temperature is not sufficient for god preservation, and, over the rear edge ,the product
could
obstruct
the
good
circulation
of
the
refrigerated
air.
The cabinet can be equipped with a lock (optional). In that case keep the keys out of
the reach of children.
WARNING:
NEVER
WET
ANY
CABINET
PART
WHERE
ELECTRICAL
COMPONENTS ARE PRESENT. NEVER FORCE ANY CABINET PART WHERE
REFRIGERATING CYCLE COMPONENTS ARE PRESENT.THE CABINET IS NOT
SUITABLE FOR WORKING IN DANGEROUS PLACES WITH RISK OF FIRE,
EXPLOSIONS AND/OR RADIATIONS.