INTRODUCTION
WARNING: This unit is intended for profesional
!
use. Read all the instructions in this manual prior
to use.
• The 366 057 meter is an oval gear model pulse transmitter.
It is intended for installation in the distribution line and
connection to a monitoring equipment.
• It is recommended that the flow rate measured is placed
approximately in the middle of the operating range of the
meter. Operation with flow near the ends of the operating
range may cause a decrease in measurement accuracy.
• The equipment includes a LED indicator of valve opening
status (see section "Installation" for proper configuration).
• Mounting, electrical installation, commissioning and
maintenance must be carried out by qualified staff.
• Only use the unit for the purposes for which it is intended.
• This
unit
has
not
commercial transactions.
INSTALLATION
This equipment is designed to be installed directly in
distribution line pipe. The meter has a 3/4" BSP connection
at the inlet and outlet. Avoid installing the unit between
rigid connections to prevent efforts transmission of the
pipeline.
It is recommended to install a pressure relief system on
the line to prevent damage from thermal expansion.
To prevent damage from dirt or solid particles carried by
the fluid is recommended the installation of a 200-mesh
strainer at the meter inlet.
For connection to the monitoring equipment keep in
mind that the meter generates 109 ppl (pulses per liter)
for proper configuration.
2
836 861 R. 04/21
SAMOA Industrial, S.A. · Pol. Ind. Porceyo, I-14 · Camino del Fontán, 831 · 33392 - Gijón - Spain · Tel.: +34 985 381 488 · www.samoaindustrial.com
been
approved
for
use
• Do not alter or modify the unit.
• Do not exceed the maximum unit working pressure. See
page 4, technical specifications.
• Use the unit with fluids and solutions which are compatible
with the moist parts of the unit. See the relevant section
of the technical specifications.
• Observe the manufacturer's safety warnings for the
fluids used.
• The meter has been manufactured with low tolerances in
order to ensure high precision over a wide range of flows
and viscosity.
in
Depending on the monitoring equipment units system,
shall be established the following settings:
MONITORING EQUIPMENT UNITS SYSTEM*
Configuration
* Using fluids with high or low viscosity, as well as if
working with high flows or very low flows, calibration may
be required.
Litres
American gallons
109 ppl
412´6 ppg
Tabla de contenido
loading

Tabla de contenido