11 Disassembly
Fault
Service LED is illuminated.
Tab. 6
Troubleshooting
11 Disassembly
DANGER
Risk of injury due to unexpected start
The following instructions must be adhered to during all maintenance, servicing, assembly, disassembly and repair work:
• Switch off the extraction system.
• Close off the compressed air supply.
• Disconnect all electrical connections.
NOTICE
• Only qualified personnel are permitted to perform work on the device or system.
• Check and wear your personal protective equipment.
• Persons without personal protective equipment must not remain near the extraction system when it is being
disassembled.
• The extraction system must not be cleaned using compressed air or a hammer.
To disassemble and dispose of the device, follow the steps in sections 6 and 7 in reverse order.
6 Putting into operation on page EN-9
7 Operation on page EN-11
Dispose of the components in accordance with legal regulations.
12 Disposal on page EN-17
EN - 16
Cause
• Phases are reversed.
• Compressed air is not connected.
• Filter is worn.
xFUME PRO
Troubleshooting
• Reverse back phases.
• Connect compressed air.
• Replace filter.
9.2 Replacing the filter
cartridges on page EN-14
BAL.0732.0 • 2020-07-09