Daikin FTXP20L5V1B Manual De Instalación
Ocultar thumbs Ver también para FTXP20L5V1B:

Enlaces rápidos

Installation manual
Daikin room air conditioner
FTXP20L5V1B
FTXP25L5V1B
FTXP35L5V1B
ATXP20L5V1B
ATXP25L5V1B
ATXP35L5V1B
FTXF20A5V1B
FTXF25A5V1B
FTXF35A5V1B
Installation manual
FTXF20B5V1B
English
Daikin room air conditioner
FTXF25B5V1B
Tabla de contenido
loading

Resumen de contenidos para Daikin FTXP20L5V1B

  • Página 1 Installation manual Daikin room air conditioner FTXP20L5V1B FTXP25L5V1B FTXP35L5V1B ATXP20L5V1B ATXP25L5V1B ATXP35L5V1B FTXF20A5V1B FTXF25A5V1B FTXF35A5V1B Installation manual FTXF20B5V1B English Daikin room air conditioner FTXF25B5V1B...
  • Página 2 3P516375-1...
  • Página 3 3P516375-2...
  • Página 4 3P516375-10G...
  • Página 5: Tabla De Contenido

    Daikin website (publicly accessible). Installing the indoor unit ............5.2.1 To install the mounting plate ........▪ The full set of latest technical data is available on the Daikin Business Portal (authentication required). 5.2.2 To drill a wall hole ............
  • Página 6: Preparation

    Ø6.4 Ø9.5 Refrigerant piping material ▪ Piping material: Phosphoric acid deoxidised seamless copper. ▪ Flare connections: Only use annealed material. ▪ Piping temper grade and thickness: Installation manual (A)(F)TXP20~35L5V1B + FTXF20~35A5V1B + FTXF20~25B5V1B Daikin room air conditioner 3P519299-1J – 2019.10...
  • Página 7: Installing The Indoor Unit

    1 Remove the front grille. INFORMATION 2 Remove 1 screw from the electrical wiring box. The removed pipe port cover can be kept in the mounting plate pocket. (A)(F)TXP20~35L5V1B + FTXF20~35A5V1B + FTXF20~25B5V1B Installation manual Daikin room air conditioner 3P519299-1J – 2019.10...
  • Página 8: To Drill A Wall Hole

    Connecting the refrigerant piping DANGER: RISK OF BURNING 5.3.1 Guidelines when connecting the refrigerant piping Take the following guidelines into account when connecting pipes: Installation manual (A)(F)TXP20~35L5V1B + FTXF20~35A5V1B + FTXF20~25B5V1B Daikin room air conditioner 3P519299-1J – 2019.10...
  • Página 9: To Connect The Refrigerant Piping To The Indoor Unit

    Small animals that make contact with electrical parts can cause malfunctions, WARNING smoke or fire. ALWAYS use multicore cable for power supply cables. (A)(F)TXP20~35L5V1B + FTXF20~35A5V1B + FTXF20~25B5V1B Installation manual Daikin room air conditioner 3P519299-1J – 2019.10...
  • Página 10: Finishing The Indoor Unit Installation

    NOTICE Be careful NOT to damage any of the surrounding parts when cutting the address jumper. Drain hose Caulk this hole with putty or caulking material. Installation manual (A)(F)TXP20~35L5V1B + FTXF20~35A5V1B + FTXF20~25B5V1B Daikin room air conditioner 3P519299-1J – 2019.10...
  • Página 11: Commissioning

    ▪ In case you could NOT complete the setting in time, commissioning checklist is also available on the Daikin turn the power supply off and wait at least 1  minute Business Portal (authentication required).
  • Página 12: To Perform A Test Run

    Disposal Dismantling of the unit and treatment of the refrigerant, oil and other parts MUST comply with the applicable legislation. Installation manual (A)(F)TXP20~35L5V1B + FTXF20~35A5V1B + FTXF20~25B5V1B Daikin room air conditioner 3P519299-1J – 2019.10...
  • Página 13: Technical Data

    9 Technical data Technical data A subset of the latest technical data is available on the regional Daikin website (publicly accessible). The full set of latest technical data is available on the Daikin Business Portal (authentication required). Wiring diagram Unified Wiring Diagram Legend For applied parts and numbering, refer to the wiring diagram on the unit.
  • Página 16 DAIKIN ISITMA VE SOĞUTMA SİSTEMLERİ SAN.TİC. A.Ş. Gülsuyu Mahallesi, Fevzi Çakmak Caddesi, Burçak Sokak, No:20, 34848 Maltepe İSTANBUL / TÜRKİYE Tel: 0216 453 27 00 Faks: 0216 671 06 00 Çağrı Merkezi: 444 999 0 Web: www.daikin.com.tr 3P519299-1J 2019.10...

Tabla de contenido