About The Box; Outdoor Unit; To Remove The Accessories From The Outdoor Unit; Unit Installation - Daikin RXF50B2V1B Manual De Instalación

Ocultar thumbs Ver también para RXF50B2V1B:
Tabla de contenido

3 About the box

WARNING
ALWAYS use multicore cable for power supply cables.
WARNING
Use an all-pole disconnection type breaker with at least
3  mm between the contact point gaps that provide full
disconnection under overvoltage category III.
WARNING
If the supply cord is damaged, it MUST be replaced by the
manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
WARNING
Do NOT connect the power supply to the indoor unit. This
could result in electrical shock or fire.
WARNING
▪ Do NOT use locally purchased electrical parts inside
the product.
▪ Do NOT branch the power supply for the drain pump,
etc. from the terminal block. This could result in
electrical shock or fire.
WARNING
Keep the interconnection wiring away from copper pipes
without thermal insulation as such pipes will be very hot.
DANGER: RISK OF ELECTROCUTION
All electrical parts (including thermistors) are powered by
the power supply. Do not touch them with bare hands.
DANGER: RISK OF ELECTROCUTION
Disconnect the power supply for more than 10  minutes,
and measure the voltage at the terminals of main circuit
capacitors or electrical components before servicing. The
voltage MUST be less than 50 V DC before you can touch
electrical components. For the location of the terminals,
see the wiring diagram.
Finishing indoor unit installation (see
installation" [ 4  20])
unit
DANGER: RISK OF ELECTROCUTION
▪ Make sure that the system is earthed properly.
▪ Turn off the power supply before servicing.
▪ Install the switch box cover before turning on the power
supply.
Commissioning (see "9 Commissioning" [ 4  20])
DANGER: RISK OF ELECTROCUTION
DANGER: RISK OF BURNING/SCALDING
CAUTION
Do NOT perform the test operation while working on
the indoor units.
When performing the test operation, NOT only the outdoor
unit, but the connected indoor unit will operate as well.
Working on an indoor unit while performing a test operation
is dangerous.
CAUTION
Do NOT insert fingers, rods or other objects into the air
inlet or outlet. Do NOT remove the fan guard. When the
fan is rotating at high speed, it will cause injury.
Installation manual
14
"8 Finishing the outdoor
3
About the box
3.1

Outdoor unit

3.1.1
To remove the accessories from the
outdoor unit
1 Lift the outdoor unit.
2 Remove the accessories at the bottom of the package.
a
b
c
a
General safety precautions
b
Outdoor unit installation manual
c
Fluorinated greenhouse gases label
d
Multilingual fluorinated greenhouse gases label
e
Drain plug (located on the bottom of the packing case)
f
Drain cap (1)
g
Drain cap (2)
h
Energy label
4

Unit installation

WARNING
Installation shall be done by an installer, the choice of
materials and installation shall comply with the applicable
legislation. In Europe, EN378 is the applicable standard.
4.1

Preparing the installation site

WARNING
The appliance shall be stored in a room without
continuously operating ignition sources (example: open
flames, an operating gas appliance or an operating electric
heater).
4.1.1
Installation site requirements of the
outdoor unit
Mind the following spacing guidelines:
b
>100
a
>50
b
>100
a
>50
(mm)
a
Air outlet
b
Air inlet
ARXM50-71+RXM42~71R2V1B + RXP50~71M2V1B +
RXA42+50B2V1B + RXF50+60B2V1B + RXF71A2V1B +
d
e
f
g
a
>350
b
>50
b
>100
a
a
>350
b
RXJ50N2V1B + ARXF50~71A2V1B
R32 split series
3P512025-9S – 2020.05
h
Tabla de contenido
loading

Tabla de contenido