6. Switch the machine off at the main switch (1) and
close the water tap.
7. Connect the short high pressure hose to the high
pressure connection (2).
8. Connect the long high pressure hose (7) to the
gun handle (8) using a spanner.
9. Connect the high pressure lance (5) to the gun (8).
10. Place the lance nozzle in the
proper position depending
on whether it is to be used
with high or low pressure
(See paragraph "Use with
detergent"). Push back the
lance nozzle for high pressure
operation and push forward
for low pressure operation.
(See sketch in paragraph "use
with detergent").
11. Finally, start up the machine at the main switch (1)
and adjust the desired pressure level by means of
the pressure control valve (10).
B- Operation of the hand Spray Gun (8)
Opening the gun: Release the lock
and pull the trigger, see sketch.
Closing the gun: Release the trigger.
During work breaks secure the hand
spray gun (8) with the lock.
Take into account that after releasing
the trigger the motor keeps running
until switching off.
C- Adjustment of the Spray Jet
Turn the pressure nozzle (5) to change from a narrow
jet to a fan jet.
Operating instructions
D- Pressure control valve
Turn the valve clockwise to increase pressure.
E- End of operation and circuit draining
1. Switch the device off at the main switch (1).
2. Remove the mains plug (9) from the socket.
3. Close the water supply tap.
4. Pull the trigger of the gun (8) and wait until no
water comes out of the gun or lance.
5. Secure the manual spray gun (8) with the lock.
6. Disconnect the device from the water supply (3).
Cleaning
The device must never be immersed in water for
cleaning, but should be cleaned with a soft dry cloth.
In case of stubborn dirt slightly dampen the cloth with
water and then wipe dry.
Storage
Disassemble all accessories from each other. Empty the
accessories and the high-pressure hose.
Take into account that if there is still water in the
high-pressure machine, frost may damage the pump
or internal piping. Therefore the device should always
be stored in rooms free from frost.
Troubleshooting
A- Device would not start up
- Check the power supply.
- Check the position of the main switch (1).
15