Application
Part No. 20 074:
Pillar usefull for:
- directly connection to cold water supply
- connection to outflow of mixed water supply
Part No. 21 027 and 21 031:
Operation is possible in conjunction with:
- Pressurized storage heaters
Operation is not possible with:
- Low-pressure storage heaters
(displacement water heaters)
Specifications
• Max. flow
8.3 L/min or 2.2 gpm/60 psi
EcoJoy
5.7 L/min or 1.5 gpm/60 psi
• Flow pressure
- min.
- recommended
- greater than 72.5 psi, fit pressure
reducing valve
• Max. operating pressure
• Test pressure
Part No. 21 027 and 21 031:
• Temperature
- max. (hot water inlet)
• Water connection
Note
Major pressure differences between hot and cold
water supply should be avoided.
1
English
Installation
Flush pipes thoroughly.
Installation and connection, see fold-out page I,
Fig. [1], [2] and [3].
Refer to the dimensional drawings on fold-out page I.
Part No. 20 074 and 21 027:
Fit swivel spout, see Fig. [1].
Part No. 21 027 and 21 031:
When assembling, the waste rod (A) has to be placed
into the body, see Fig. [2].
Fit pop-up drain (28 957), see fold-out page II, ensure
that flange of pop-up drain is sealed.
Open cold and hot water-supply and check
connections for leakage.
Maintenance
Inspect and clean all parts, replace as necessary and
7.25 psi
grease with special grease.
14.5 - 72.5 psi
Shut off cold and hot water supply!
145 psi
I. Replacing the headpart, see Fig. [4].
232 psi
1. Remove handle (18 026) or lever (18 027).
2. Unscrew screw (B) and pull off snap insert (C).
3. Unscrew headpart (D) using a 17mm socket wrench.
4. Change complete headpart (D) or O-ring (E).
176 °F
II. Flow regulator, see fold-out page II.
cold - RH
Unscrew and clean flow regulator (13 935).
hot - LH
Assemble in reverse order.
Replacement parts, see fold-out page II ( * = special
accessories).
Care
Instructions for care of this single lever faucet will be
found in the Limited Warranty supplement.