Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

Operating Instructions & Parts Manual
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and
others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for
future reference.
Dyna-Glo
Gas Construction Heater
Description
Dyna-Glo Delux model RMC-FA150NGDGD is a natural gas fired construction
heater, having a built-in thermostat, and a 150,000 BTU/Hr rating. The heater
uses natural gas for com bustion and electricity to operate the motor and fan.
It is primarily to be used to temporarily heat well-ventilated buildings under
construction, alteration or repair. This heater should be utilized in sheltered, well-
ventilated areas, but never in occupied dwellings.
Specifications
Output Rating
Model
BTU/Hr
RMC-FA150NGDGD
150,000
Manifold
Model
Pressure
RMC-FA150NGDGD
4" W.C.
Model
Ignition
RMC-FA150NGDGD
Continuous spark
Table of Contents
Description . . . . . . . . . . . . . . . . . . . . . . .1
Specifications. . . . . . . . . . . . . . . . . . . . . .1
Unpacking . . . . . . . . . . . . . . . . . . . . . . . 1
General Safety Information . . . . . . . . 1-3
Principals of Operation. . . . . . . . . . . . . .3
Ventilation. . . . . . . . . . . . . . . . . . . . . . . .3
Installation. . . . . . . . . . . . . . . . . . . . . . . .4
Operation . . . . . . . . . . . . . . . . . . . . . . . .4
Maintenance . . . . . . . . . . . . . . . . . . . . 4-5
Storage . . . . . . . . . . . . . . . . . . . . . . . . . .5
Wiring Diagram. . . . . . . . . . . . . . . . . . . .6
Repair Parts Illustration . . . . . . . . . . . . .7
Repair Parts List. . . . . . . . . . . . . . . . . . . .7
Troubleshooting Chart . . . . . . . . . . . . . .8
Warranty . . . . . . . . . . . . . . . . . . . . . . . . .9
Unpacking
1. Unpack all materials used to protect
the heater inside of carton. Retain
plastic caps attached to exposed
Delux Natural
®
US
ANS Z83.7-2011 CSA 2.14-2011 Construction Heater
Fuel
Fuel
Consumption
Natural Gas Only 146 Cubic ft/h
(4.13 m
/h)
3
Maximum Supply
Minimum Supply
Pressure to Heater
Pressure to Heater
1/2 PSI
5" W.C.
Spark Plug
Gap (Inches)
.12
(3.05 mm)
Page
fittings for use during storage.
2. Remove heater, accessories and all
hardware from carton.
3. Inspect all items for damage that may
have occurred during shipment.
General Safety Information
Make certain you read and understand
all warnings. Keep these instructions for
reference. They are your guide to safe
and proper operation of this heater.
Safety information appears throughout
these instructions. Pay close attention
to them. Below are definitions for the
safety information listed throughout
this manual.
Indicates an
DANGER
im minen tly
hazardous situation which, if not
avoided, WILL result in death or serious
injury.
Indicates a poten­
WARNING
Printed in China
Figure 1 - Model RMC-FA150NGDGD
Hot Air Output
(CFM Approx)
Motor
435
3440 RPM
Temperature
Control
Built-In Thermostat
Size
L x W x H (Inches)
25 x 9.4 x 15.5
(63.5 x 23.9 x 39.4 cm)
tially hazardous situation which, if not
avoided, COULD result in death or serious
injury.
CAUTION
situa tion which, if not avoided, MAY
result in minor or moderate injury.
IMPORTANT: Not every possible cir-
cumstance that might involve a hazard
can be anticipated. The warnings in this
manual and on tags or decals affixed to
the unit are therefore not all-inclusive.
If a procedure, work method, or oper-
ating technique not specifically recom-
mend ed by is used, you must make sure
it is safe for you and others.
You should also ensure that equipment
will not be damaged or made unsafe by
the operating or maintenance method
you choose.
Consumer: Retain this manual for future
reference.
RMC-FA150NGDGD
Electric Motor
Input
Amperage
120V/60Hz, 1/9 HP 0.7
Indicates a poten­
tially hazardous
PROFESSIONAL GRADE
IMNGF150DGD - GBW
Tabla de contenido
loading

Resumen de contenidos para Dyna-Glo RMC-FA150NGDGD

  • Página 20 GHP Group, Inc. 6440 W Howard St GHP Group, Inc. Niles, IL 60714-3302 6440 W Howard St Niles, IL 60714-3302 GHP Group, Inc. 6440 W Howard St GHP Group, Inc. Niles, IL 60714-3302 6440 W Howard St Niles, IL 60714-3302...
  • Página 21: Descripción

    Delux ® Descripción El modelo Dyna-Glo Delux RMC-FA150NGDGD es un calentador a gas natural para construcciones, que tiene un termostato incorporado y una capacidad útil de calor de 150,000 BTU/Hr . Este calentador usa gas natural para la combustión y electricidad para hacer funcionar el motor y el ventilador . La unidad ha sido diseñada principalmente para proporcionar calefacción temporal en edificios bien...
  • Página 22: Calentadores De Gas Natural Para Construcciones Dyna-Glo

    RMC-FA150NGDGD Manual de Instrucciones de Operación y Lista de Partes Dyna-Glo Delux Calentadores de Gas Natural para Construcciones Dyna-Glo ® Delux ¡NUNCA DEJE EL CALENTADOR DESATENDIDO CUANDO ESTÉ ENCENDIDO! Información de Seguridad acuerdo a las normas ANS Z83 .7 CSA Nacional de Gas Combustible NFPA54/ General (Continuación)
  • Página 23: Componentes Principales Para El

    RMC-FA150NGDGD Manual de Instrucciones de Operación y Lista de Partes Dyna-Glo Delux Modelo RMC-FA150NGDGD ¡NUNCA DEJE EL CALENTADOR DESATENDIDO CUANDO ESTÉ ENCENDIDO! Información de Seguridad SEGURIDAD – No utilice el calentador si está General (Continuación) alterado . El sistema apaga el calentador si la llama se extingue .
  • Página 24: Instalación

    RMC-FA150NGDGD Manual de Instrucciones de Operación y Lista de Partes Dyna-Glo Delux Calentadores de Gas Natural para Construcciones Dyna-Glo ® Delux ¡NUNCA DEJE EL CALENTADOR DESATENDIDO CUANDO ESTÉ ENCENDIDO! Instalación 4 . Abra lentamente la válvula en el 4 . De acuerdo con los requisitos del suministro del gas natural .
  • Página 25: Mantenimiento

    RMC-FA150NGDGD Manual de Instrucciones de Operación y Lista de Partes Dyna-Glo Delux Modelo RMC-FA150NGDGD ¡NUNCA DEJE EL CALENTADOR DESATENDIDO CUANDO ESTÉ ENCENDIDO! Ventilador Mantenimiento Desmonte la protección del Arandela ventilador . No intente darle Motor mantenimiento VENTILADOR al calentador mientras esté enchufado,...
  • Página 26: Diagrama Eléctrico

    RMC-FA150NGDGD Manual de Instrucciones de Operación y Lista de Partes Dyna-Glo Delux Calentadores de Gas Natural para Construcciones Dyna-Glo ® Delux ¡NUNCA DEJE EL CALENTADOR DESATENDIDO CUANDO ESTÉ ENCENDIDO! Diagramas Eléctricos Interruptor Amarillo de límite alto Válvula de gas Blanco Interruptor Bujía...
  • Página 27 RMC-FA150NGDGD Manual de Instrucciones de Operación y Lista de Partes Dyna-Glo Delux Para Obtener Partes de Reparación Llame al 1-877-447-4768 Por favor proporciónenos la siguiente información: - Número de modelo ¡NUNCA DEJE EL CALENTADOR - Número de serie (si lo tiene) - Descripción de la parte y número que le corresponde...
  • Página 28: Tabla De Identificación De Problemas

    RMC-FA150NGDGD Manual de Instrucciones de Operación y Lista de Partes Dyna-Glo Delux Calentadores de Gas Natural para Construcciones Dyna-Glo ® Delux ¡NUNCA DEJE EL CALENTADOR DESATENDIDO CUANDO ESTÉ ENCENDIDO! Tabla de Identificación de Problemas Síntoma Causa(s) Posible(s) Medida Correctiva El ventilador no gira cuando 1 .
  • Página 29 GARANTÍA RMC-FA150NGDGD Manual de Instrucciones de Operación y Lista de Partes Dyna-Glo Delux GARANTÍA LIMITADA: Esta garantía limitada es extendida al comprador original al detalle de este Calentador de Aire Forcado/ Convección/ Radiante y garantiza contra cualquier defecto en materiales y funcionamiento por un período de un (1) año desde la fecha de venta al detalle. GHP Group,Inc., como su opción, proporcionará...
  • Página 30: Registro De Garantía

    REGISTRO DE GARANTÍA IMPORTANTE: Lo invitamos a completar nuestro formulario de registro de garantía dentro de los siguientes 14 días a la fecha de compra. Usted también puede registrar su garantía en el internet en www.ghpgroupinc.com. Complete el número de serie. Conserve esta parte de la tarjeta como su comprobante.

Tabla de contenido