S&P SILENT DESIGN Serie Manual Del Usuario página 14

Ocultar thumbs Ver también para SILENT DESIGN Serie:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1
voltage and frequency as indicated on
the rating plate of the unit. The units
are manufactured with double electri-
cal insulation (Class II) and therefore
they do not need an earth connection.
In addition to the switch shown in the
installation drawing/diagram, there
must be an All Pole switch in the fi xed
wiring with a contact opening of min 3
mm.
The electrical cable must enter the SI-
LENT DESIGN through the cable entry
(4).
Once the cable has been introduced
proceed using the electrical wiring dia-
gram applicable to the selected model.
SILENT CHZ DESIGN
Models provided with an electronic hu-
midistat which can be adjusted from
60% to 90 % RH (Relative Humidity) and
with a timer, adjustable between 1 and
30 minutes. The desired humidity level
and run on time are selected by means
of 8 dip-switches placed on the print-
ed circuit board, and easily accessible.
Each dip-switch has two positions [ON
(1) and OFF (0)] which are selected with
the small plastic screwdriver supplied
with the fan:
The functions of these dip-switches are:
– Switch 1: "Interval" function selec-
tion (yes or no)
– Switches 2 and 3: Interval time set-
tings between 4, 8, 12 and 24 hours
14
– Switches 4 and 5: Humidistat set-
tings between 60, 70, 80 and 90%
– Switches 6 and 7: Over-run timer
settings between 1, 5, 15 and 30
minutes
– Switch 8: Start-up timer function
(yes or no)
Automatic operation
The extractor is connected to the main
supply with only two wires (Fig.4)
(Fig.6). The humidistat causes the ex-
tractor to operate automatically when
the humidity level in the room is higher
than the set level. The extractor will
stop automatically when the humidity
drops below the selected level (-5% or
+10%) and after the selected period set
on the over-run timer.
"Interval" functions
This function is useful when the extract
fan is installed in very wet (near the
sea) or the ambiance exceeds the set
Tabla de contenido
loading

Este manual también es adecuado para:

Silent-100 designSilent-200 designSilent-300 design

Tabla de contenido