COMMISSIONING THE DIMMER
LED
45
25,3
TE
OPERATING MODES
Note: lamp(s) switch-on, light intensity control, switch-off take place via remote buttons connected to the Dimmer
OPERATION WITH MEMORY (factory setting)
Whenever it is switched on, the Dimmer sets the same brightness level set previously.
Note: the first time it is switched on (new device), it sets the highest brightness level.
OPERATION WITHOUT MEMORY
Whenever it is switched on, the Dimmer sets the highest brightness level.
Disabling/enabling operation with memory
1. Cut off the 230V power supply
2. Press and hold one of the remote buttons connected to the Dimmer.
3. Restore the 230V power supply and hold down the remote button (for at least 3 seconds).
4. After 3 seconds, the lamp(s) connected to the Dimmer will switch on to indicate the setting change:
1 slow
flashing
for
memory enabling
2 slow
flashing
for memory disabling.
5.
Release the remote button
TURNING THE LAMPS ON AND OFF
The lamps are turned on and off by briefly pressing the remote button.
Note: in the event of a power cut, if the lamps are on, they go out. When the power is back, the lamps remain off.
The lamps are always turned back on by briefly pressing a remote button.
LAMP SWITCH-ON MODE
Soft start the switch on is gradual, up to the setted level.
LIGHT INTENSITY ADJUSTMENT
1. Briefly press the remote button to switch on the lamps
2.
Press and hold the button again: the brightness is regulated
3. Once the desired luminosity is obtained, release the button: it will be saved and restored whenever the lamp is switched on
again (if operation with memory is enabled).
If you wish to reverse the adjustment direction (from upward to downward or vice versa), release the button during adjustment,
then press it again and hold it.
OVERLOAD or SHORT-CIRCUIT PROTECTION
To protect the DIMMER, install an external F2.5AH 250V fast fuse on the mains phase (L)
(see electrical connections on page ).
THERMAL PROTECTION
In the event of Dimmer overheating, the thermal protection will trigger and minimise the luminous adjustment of the lamps; in this
situation the load can only be switched off or on by operating a remote button. If the temperature continues to increase regardless, the
lamps will be switched off automatically after passing a second thermal protection threshold.
Not : e identify and eliminate the cause of the overheating
(
example: make sure that the connected loads do not exceed the values stated in the table: "Controllable loads"
DISPOSAL OF OLD ELECTRICAL AND ELECTRONIC EQUIPMENT
When this symbol is found on the product or on its packaging, it indicates that this product cannot be disposed of as household waste.
It must be delivered to a specific collection point where electrical and electronic equipment is recycled, such as:
- retail outlets, if a new product is bought, similar to that being disposed of
- local collection points (waste collection centres, local recycling centres, etc).
By ensuring that the product is disposed of correctly, you will help prevent potential negative consequences for the environment and health, which can be caused by
this product being disposed of inappropriately. Recycling the materials will help conserve natural resources. For more detailed information about recycling this
product, please contact your Local Council, household waste disposal service or the shop where you purchased the product.
4
45
For wall mounting in an electrical
panel, use ø 4 mm screws.
58,7
52
«TE» Trailing Edge
lamp
dimming
mode
.
, the setting will be saved.
3
Use only one dimmer inside
the same flush-mounted box
and do not insert another
device that generates heat
After carrying out electrical connection correctly, switch on the 230V mains voltage.
The Dimmer does not require any initial configuration.
The Dimmer LED lights up with 2 flashes every 2 seconds only when the load is off.
upwards
starting from the previously set
Example: in recessed box (type 503)
ted
level.
).