Placing the probe in configuration mode
1
2
LED check
> 5 s
3
3
8
Deflect the stylus and hold
Key to the symbols
deflected until after the battery
status has been displayed at the
LED short flash
end of the review sequence.
LED long flash
Deflect the stylus for less than 4 seconds
to move to the next menu option.
Battery status
Battery good
Battery low
Deflect the stylus for more than
or
4 seconds to move to the next menu.
To exit, leave the stylus untouched for
more than 20 seconds.
To change the switch on method,
go to the next page.