Connect the Network Cables
Note: Refer to the illustration on page 1.
1. Connect an RJ-45 cable to VisionView's Ethernet port, and connect the
other end of the cable to a switch/router, as applicable.
2. Alternatively, connect a Cognex vision sensor directly to VisionView's
Ethernet port.
Note: The VisionView Ethernet port does not provide Power over
Ethernet (PoE) to Cognex sensors.
Connect the Power Cable
Note: Refer to the illustration on page 1.
1. Verify the 24VDC power supply being used is unplugged and not receiving
power.
2. Attach the power cable's Ground wire to Pin 1 and the +24V wire to Pin 2 on
the green power connector supplied with VisionView. (Refer to Power
Connector Specifications on page 9.)
3. Insert the green power connector into the Power Connector port.
CAUTION:
power connector.
4. Restore power to the 24VDC power supply and turn it on if necessary.
5. Turn the VisionView Power Switch (located directly below the Power
Connector port) to the ON position.
Do not connect AC power directly to the VisionView
7