J-SRX210 Services Gateway with Integrated Convergence Services
(J-SRX210H-P-MGW) Back Panel
Callout
Description
1
Power supply input
2
Cable tie holder
3
Grounding point
J-SRX210 Services Gateway Models
The following four models of J-SRX210 Services Gateway are available:
Device
DDR Memory
J-SRX210B
512 MB
J-SRX210H
1 GB
J-SRX210H-POE
1 GB
J-SRX210H-P-MGW
1 GB
NOTE:
On the J-SRX210H-PoE and J-SRX210H-P-MGW models, Power over Ethernet
(PoE) of 50 watts is supported across 4 ports (ge-0/0/0, ge-0/0/1, fe-0/0/2, and fe-0/0/3).
Connecting and Configuring the J-SRX210 Services Gateway
Use the instructions below to connect and set up any model of the J-SRX210 Services
Gateway to protect your network. Refer to the LEDs on the front panel of the device to
help you determine the status of the device.
Part 1: Connect the Services Gateway to Earth Ground
1.
Obtain a grounding cable—14 AWG single-strand, 4 A—with a ring-type,
vinyl-insulated TV14-6R lug or equivalent attached by a licensed electrician.
2.
Connect the grounding cable to a proper earth ground.
3.
Place the grounding cable lug over the grounding point on the upper rear of the
chassis, and secure the lug with one 6-32 UNC screw.
All manuals and user guides at all-guides.com
Callout
Description
4
Lock for security cable
5
ExpressCard slot
Power over Ethernet
Voice Support
No
No
No
No
Yes
No
Yes
Yes
Part 2: Connect the Power Cable to the Device
Connect the power cable to the device and a power source. We recommend using a
surge protector. Note the following indications:
POWER LED (green): The device is receiving power.
STATUS LED (green): The device is operating normally.
ALARM LED (amber): The device is operating normally, and may glow amber as a
rescue configuration has not been set. This is not a panic condition.
mPIM LED (off): The Mini-Physical Interface Module (Mini-PIM) is not present or is
not detected by the device. If this LED is green and steadily on, it indicates that the
Mini-PIM is functioning normally.
NOTE:
After a rescue configuration has been set, an amber ALARM LED indicates a
minor alarm, and a solid red ALARM LED indicates that a major problem exists on the
services gateway.
NOTE:
You must allow the device between 5 and 7 minutes to boot up after you have
powered it on. Wait until the STATUS LED is solid green before proceeding to the next
part.
Part 3: Connect the Management Device
Connect the management device to the services gateway using either of the following
methods:
Connect an RJ-45 cable (Ethernet cable) from one of the following ports on the front
panel to the Ethernet port on the management device (workstation or laptop):
ge-0/0/1
fe-0/0/2 through fe-0/0/7
We recommend this connection method. If you are using this method to connect,
proceed with Part 4.
Connect an RJ-45 cable (Ethernet cable) from the port labeled CONSOLE to the
supplied DB-9 adapter, which then connects to the serial port on the management
device. (Serial port settings: 9600 8-N-1.)
If you are using this method to connect, proceed with the CLI configuration
instructions available in the Branch SRX Series Services Gateways Golden
Configurations at http://www.juniper.net/us/en/local/pdf/app-notes/3500153-en.pdf.
See the illustration below for details on connecting a management interface.