2.1.2 Electrical Installation
These equipments has been designed for 110, 220 or 230 V (single voltage according to
the equipment purchased). When receiving the equipment check the voltage indicated on
the cord label.
The cord has a plug with three pins, the middle one is ground. It is mandatory the three
pins to be duly connected before to start the machine.
IMPORTANT
Make sure the network voltage is the same as the voltage indicated on the cord
label.
2.2 Pre Operation
Before using your equipment, should you wash all parts that come into contact with the
product to be processed, with water and neutral SOAP (see item 3.4 cleaning).
Verify that the equipment this firm in your workplace.
IMPORTANT
When mounting the full mouth, do not over tighten the wheel no. 03 (fig. 01), thus
avoiding locking or breaking of the internal components.
The assembly of the machine mouth must be done so that the pin fits tightly into the box
cover as shown in Pincture 03.
Tighten the knob so that the mouth is completely fixed.
The assembly of the internal components must be carried out in reverse.
MOUTH PIN
MOUTH
GUIDE HOLE
PICTURE 03
BOX
COVER
KNOB