Error Messages; How Does The Body Analyser Work; Technical Data; Conditions To Use - ADE BA 710 Manual Del Usuario

Tabla de contenido
Thank you for your decision to purchase this high quality body analyser scale. Please
read this instruction manual prior to the start up and keep this user instruction careful
so as to have this information on hand whenever it is needed.

1. How does the body analyser work?

Through this new revolutionary scale you will be able to get information about your
body composition with reference to your weight, body fat %, body water % and muscle
mass %. First of all you have to enter once your personal data like body height, age,
gender under your selected personal memory location. Afterwards a measurement is
as simple as on a normal bathroom scale. You have only to push your personal
memory location, step on the scale and within a few seconds your weight, body fat,
body water and muscle mass will be indicated. The analysis is based on the
measurement of the body's electrical resistance. A low, safe electrical signal passes
freely through fluids contained in lean tissue, such as muscle and blood, but meets
resistance passing through fat tissue. The body analyser accurately measures the
resistance and with reference to your personal data use it to calculate elements of
body composition.

2. Conditions to use

If possible the measurement should be done undressed but always barefoot.
By nature a body is subject of fluctuations (for example: loss of water after taking
exercise or after a sauna visit, after a meal, etc.). To enable comparable readings it is
important to take the measurements as possible always under the same conditions.
In order to ensure that the results of analysis are accurate and consistent, please keep
the measurement conditions constant always at the same daytime. In the morning,
directly after you've woken up, your body will be dehydrated and also the majority of
fluid will be stored in the central trunk area. This means that the resistance is relatively
high because of the poor conductivity in the body. By intensify moving during the day
progresses the fluid becomes more evenly distributed through the limbs and
increasing the accuracy of the readings. To get a realistic result it is important to take
your readings at the same time and under the same conditions every day. The easiest
way to stick the rule, measure always in the morning, 15 minutes after you've got up,
either before or after you've gone to the bathroom.
In spite of a very low electrical signal, this body analyzer is not suitable for
persons with heart pacemaker or other electronic medical implants! There is no
risk for persons with none electronic implant for instance a titanium plate in the knee.
However, metal conducts the electric current extremely well and therefore the scale
implicates the body fat value "beautified" – means the actual body fat value is higher
as indicated. However, tendencies may be determined as well.
2

7. Error Messages

„O_LD" =
Overload
The weight exceeds the maximum capacity of 180 kg. Please
immediately remove the critical load to avoid load cell damage.
„LO" =
Batteries are used up
Please replace the batteries with the intended type (1 x CR2032).
„Err" =
Incorrect weighing- or measuring process
For example, the scale is placed unstable or you do not remain
stationary on the weighing platform.

8. Technical Data

Capacity x graduation:
max. 180 kg x 100 g
Display resolution:
body fat: 0.1%
Display resolution:
body water: 0.1%
Display resolution:
muscle mass: 0.1%
Personal memory keys:
12 positions
10 – 85 years
Age:
75 – 215 cm
Body height:
Dimensions:
300 mm x 40 mm x 330 mm
Batteries:
1 x CR 2032 (included)
Subject to technical modifications
9. Warranty
ADE warrants for a period of 3 years from the date of purchase that it will remedy any
defects due to faulty material or workmanship free of charge by repair or replacement.
When purchasing, please have the warranty coupon signed and stamped by the dealer.
When making a guarantee claim, please return the weighing scale together with the
guarantee card including the reason of complaint to your dealer.
CE-Conformity. This device features radio interference
suppression in compliance with valid EC Regulation 2004/108
Note: The displayed value may be adversely affected under extreme electromagnetic
influences, e.g. when using a radio unit in the immediate vicinity of the device. Once the
interference has been rectified, the product can once again be used for its intended
purpose. The device may have to be switched on again.
7
Tabla de contenido
loading