Etherma solamagic S1 Instrucciones De Montaje Y Uso página 117

Fuente: etherma.com
Ocultar thumbs Ver también para solamagic S1:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 162
3. Installation, radiant heater S3
with ceiling installation frame
(device type IR 05028)
General instructions
• The ceiling installation frame is suitable for installation fastening in ceiling panels of
min. thickness 10 mm and max. thickness 30 mm (Comfortversion max. 25 mm).
• The installation must not change or impair the existing ceiling stand.
• Two people are required for the installation.
• The electrical connection must be made outside the installation frame
(inspection access).
• The minimum distances given in appendix 2 indicate the free space for air
circulation. These must not be reduced or covered by insulation or similar.
Installation steps:
a) Variant Direct Fitting:
• Create a ceiling cut-out with the dimensions 280 mm x 850 mm.
• Drill fastening holes in the ceiling panel.
• Connect the device to the electricity, but do not switch on.
• Position the device in the ceiling cut-out.
Warning:
The connecting cable must be led away directly from the device. It must be
routed in the installation space away from the cut-out area.
• From the outside screw the installation frame to the ceiling panel using six 4 mm
diameter screws.
Warning:
Ensure the screws are tightly seated in the threads.
If necessary, use additional mounting frames (accessories)!