Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

Optional Accessory: Wall Cover-Up Plate F61-2663, 6 3/4" W x 4 1/2" H
INDEX
Thermostat Installation
2-4
Wiring
2
3-4
5-7
5
6
6
7
7-8
8
SPECIFICATIONS
Electrical Rating:
Battery Power ..................................... 20 to 30 VAC, NEC Class II, 50/60 Hz
Input-Hardwire .................................... 20 to 30 VAC, NEC Class II, 50/60 Hz
Terminal Load .......................................... 1.5 A per terminal, 2.5A maximum all terminals combined
Setpoint Range ........................................ 45° to 99° F (7° to 37° C)
Rated Differentials (@ 6°F/ Hr):
Fast
Heat Pump (Heat)................................ 0.9°F
Heat Pump (Cool) ................................ 0.9°F
Auxiliary Heat ...................................... 0.5°F
Operating Ambient .................................. 32°F to +105°F (0° to +41°C)
Display Temperature Range ....................... 32°F to +99°F (0 to 37°C)
Operating Humidity ................................. 90% non-condensing maximum
Shipping Temperature Range ................... -20°F to + 150°F (-29° to +65°C)
Thermostat Dimensions ........................... 3-3/4" H x 6" W x 1-1/8" D
www.white-rodgers.com
www.emersonclimate.com
1F83H-21PR (Programmable)
Installation and Operating Instructions
80 Series Heat Pump Thermostat
Battery Powered or Hardwired with Common
Maximum
Thermostat Applications
Stages
Heat/ Cool
Single Stage Compressor, Heat Pump
Systems (air source or geothermal) -
1 Stage Aux/Emergency Heat
MERCURY NOTICE: This product does not contain
mercury. However, this product may replace a product
that contains mercury. Mercury and products containing
mercury must not be discarded in household trash.
Refer to www.thermostat-recycle.org for information
on disposing of products containing mercury.
Med
Slow
1.2°F
1.7°F
1.2°F
1.7°F
0.75°F
1.9°F
PART NO. 37-7511A-EN
WIRING
Refer to equipment manufacturer's instructions for specific system wiring information. After
wiring, see INSTALLER MENU for proper thermostat configuration. Wiring table shown are
for typical systems and describe the thermostat terminal functions.
Terminal Designations
*Cut W2/E jumper when separate heat sources are used for W2 and E.
IMPORTANT: For Dual Fuel Heat Pump applications, be sure to turn on the Duel Fuel Logic option
(found in the Installer's Menu)
2/1
Precautions
• Do not exceed the specification ratings.
• All wiring must conform to local and national electrical codes and ordinances.
• This control is a precision instrument, and should be handled carefully. Rough handing or
distorting components could cause the control to malfunction.
!
Do not use on circuits exceeding specified voltage.
Higher voltage will damage control and could
cause shock or fire hazard.
Do not short out terminals on gas valve or primary
control to test. Short or incorrect wiring will burn
out thermostat and could cause personal injury
and/or property damage.
1504
THERMOSTAT INSTALLATION
R
Power (24V)
Changeover Terminal-Energized in Cool (O) or Heat (B)
O/B
for Heat Pump or Damper Systems
Y
Heat and Cool Mode 1st Stage Compressor
G
Fan Relay
E*
Auxiliary only Heat Mode (Emergency Heat)
C
Common wire for 24V (optional with batteries)
Heat Pump malfunction / Diagnostic terminal
L
(input signal requires common)
W2*
Heat Mode - 2nd stage
WARNING
To prevent electrical shock and/or equipment
damage, disconnect electrical power to system,
at main fuse or circuit breaker box,until
Terminal Function
Leveling Thermostat
Leveling is for appearance only and
will not affect thermostat operation.
CAUTION
!
installation is complete.
2

Capítulos

Tabla de contenido
loading

Resumen de contenidos para Emerson 80 Serie

  • Página 1: Tabla De Contenido

    1F83H-21PR (Programmable) THERMOSTAT INSTALLATION Installation and Operating Instructions 80 Series Heat Pump Thermostat WIRING Battery Powered or Hardwired with Common Refer to equipment manufacturer’s instructions for specific system wiring information. After wiring, see INSTALLER MENU for proper thermostat configuration. Wiring table shown are for typical systems and describe the thermostat terminal functions.
  • Página 2: Installer Menu

    INSTALLER MENU (C0ntinued) Battery Location Settings Installer’s Menu # Default Setting Description Premium AA alkaline batteries (flashing icons) (Hold Menu 8 Seconds) (Press are required when C-wire is °F – Fahrenheit not available. When C-wire is Fahrenheit or Celsius °F °C –...
  • Página 3: Using The Thermostat

    USER MENU USING THE THERMOSTAT To customize thermostat settings, press the Menu button from the home screen. Use the buttons to highlight Settings and press Next. Use Next and Back to navigate THERMOSTAT OVERVIEW through menu items. Press to change the setting. Before you begin using your thermostat, you should be familiar with its features, display and the location/operation of the thermostat buttons and switches.
  • Página 4: Thermostat Schedule

    White-Rodgers is a business of Emerson Electric Co. (Troubleshooting continued on next page) The Emerson logo is a trademark and service mark www.white-rodgers.com of Emerson Electric Co. www.emersonclimate.com...
  • Página 5: Installation Du Thermostat

    1F83H-21PR (programmable) INSTALLATION DU THERMOSTAT Instructions d’installation et d’utilisation Thermostat avec thermopompe série 80 CÂBLAGE Alimentation par piles ou câblée avec fil commun Consultez le mode d’emploi du fabricant de l’appareil pour les informations spécifiques au câblage du système. Après le câblage, consultez la section MENU DE L’INSTALLATEUR pour configurer correctement le thermostat.
  • Página 6: Menu De L'installateur

    MENU DE L’INSTALLATEUR (suite) Emplacement des piles Num. de menu Réglage par Réglages Des piles AA de qualité sont d’installateur Description défaut requises lorsqu’un fil commun (enfoncez Menu 8 (appuyez sur (icônes clignotantes) secondes) n’est pas disponible. Lorsqu’il est °F – Fahrenheit disponible, les piles offrent alors Fahrenheit ou Celsius °F...
  • Página 7: Utilisation Du Thermostat

    MENU DE L’UTILISATEUR UTILISATION DU THERMOSTAT Pour personnaliser les réglages du thermostat, appuyez sur le bouton Menu à partir de l’écran d’accueil. Utilisez les boutons pour sélectionner Settings (Réglages) puis appuyez sur Next APERÇU DU THERMOSTAT (Suivant). Utilisez Next (Suivant) et Back (Précédent) pour naviguer dans les articles du menu. Avant d’utiliser le thermostat, vous devriez être familier avec ses fonctions, son affichage et Appuyez sur pour modifier le réglage.
  • Página 8: Dépannage

    White-Rodgers est une entreprise ou un technicien pour vérifier si le chauffage fonctionne d’Emerson Electric Co. correctement. Le logo d’Emerson est une marque (suite du dépannage à la page suivante) de commerce et une marque de www.white-rodgers.com service d’Emerson Electric Co.
  • Página 9 1F83H-21NP (No Programable) INSTALACIÓN DEL TERMOSTATO Instrucciones de instalación y operación Termostato de bomba de calor Serie CONEXIONES CONEX Alimentación por pilas o conexión por cable con neutro Consulte las instrucciones del fabricante del equipo para obtener información específica de las Consulte conexiones.
  • Página 10: Menú De Instalación

    MENÚ DE INSTALACIÓN (continuación) MENÚ Ubicación Menú de instalación Menú de Configuración Opciones de las pilas N° N° Descripción predeterminada (Mantenga presionado (Presione (Mantenga Se deben usar pilas alcalinas (iconos intermitentes) Menu durante 8 segundos) Menu dura AA de buena calidad cuando no °F –...
  • Página 11: Cómo Usar El Termostato

    MENÚ DEL USUARIO MENÚ CÓMO USAR EL TERMOSTATO Para personalizar las opciones del termostato, presione el botón Menu desde la pantalla de inicio. Para perso Use Next (siguiente) para desplazarse por los elementos del menú. Presione para cambiar la Use Next DESCRIPCIÓN GENERAL DEL TERMOSTATO opción.
  • Página 12: Solución De Problemas

    LÍNEA DE AYUDA PARA EL USUARIO: 1-800-284-2925 termómetro White-Rodgers es una empresa (La Solución de problemas continúa en la página siguiente) de Emerson Electric Co. El logotipo de Emerson es una marca comercial y una marca de www.white-rodgers.com servicio de Emerson Electric Co. www.emersonclimate.com...

Este manual también es adecuado para:

1f83h-21pr1f83h-21np

Tabla de contenido