sent to the 'iVAC Pro Switch', instructing it to turn on. As the
Mode Switch is transferred from On to Off, a transmission is
sent to the 'iVAC Pro Switch', instructing it to turn off.
4.2 Program Switch
The Program Switch is accessed through the Program
Switch cover located in the base of the unit. It enables the
programming of the System Address and the Tool Address.
4.3 System Address
A System consists of an 'iVAC Pro Switch' and up to eight
'iVAC Pro Tools' that are intended to work together.
By means of the Program Switch, the 'iVAC Pro Tool' can be
assigned to work on one of four System Addresses, A, B, C
or D. The System Address is to enable up to four systems to
operate independently while within communication range of
each other.