MAINTENANCE

10
Maintenance
11

Technical specifications

Recommended sensing range for the best performance
Sensing range max.
Light spot diameter/distance
Supply voltage U
B
Ripple
Output current I
max.
Current consumption
Switching frequency
Max. response time
Enclosure rating
Protection class
Circuit protection
Ambient operating temperature
1)
Object with 90 % remission (based on standard white DIN 5033)
Limit values. U
connections reverse-polarity protected. Residual ripple max 5 V
2)
B
3)
With light / dark ratio 1:1
4)
Signal transit time with resistive load
5)
Reference voltage DC 50 V
6)
A = U
-connections reverse polarity protected
B
B = inputs and output reverse-polarity protected
D = outputs overcurrent and short-circuit protected
12
NOTE
Disposal of batteries, electric and electronic devices
According to international directives, batteries, accumulators and electrical or
electronic devices must not be disposed of in general waste.
The owner is obliged by law to return this devices at the end of their life to the
respective public collection points.
WEEE:
This symbol on the product, its package or in this document,
indicates that a product is subject to these regulations.
SICK sensors are maintenance-free.
We recommend doing the following regularly:
Clean the external lens surfaces
Check the screw connections and plug-in connections
No modifications may be made to devices.
Subject to change without notice. Specified product properties and technical data are
not written guarantees.
WTF4FD
40 mm ... 60 mm
5 mm ... 100 mm (Typ)
2 x (0,5 x 1,5 mm) (50 mm) (Typ)
DC 10 ... 30 V
≤ 5 Vss
≤ 100 mA
25 mA
750 Hz
3)
650 µs
4)
IP66, IP67
III
5)
A, B, D
6)
–40 °C ... +60 °C
PP
1)
2)
8025301 / 2020-11-13 | SICK
Subject to change without notice