5C. ELECTRICAL INSTALLATION POWERFOIL D, POWERFOIL BREEZE CONT.
Connect and Position Cable with Cord Grip
Connect the cable with cord grip to the static tube cable. Starting below the VFD housing, insert the connected
wiring harnesses between the VFD housing and motor frame and pull them up between the housing and frame.
Install Cord Grip
Pull the wiring harnesses up between the VFD housing and motor
frame until the cord grip reaches the top of the VFD housing. Install
the cord grip and nut in the back left hole on top of the housing.
The VFD's RJ45 connector may need to be removed to tighten the
cord grip nut. Ensure the RJ45 connector is reconnected after the
cord grip is installed.
If the back left hole is not available, remove the cord grip from the
center hole and install the cable with cord grip. Route fi re relay wiring
through the new cord grip. The cord grip nut is not needed when
installing the cord grip in the center hole.
Option 1
Back Left Hole
Use if available.
Option 2
Center Hole
Replace cord grip.