Urmet 1099/811 Guía Rápida página 12

Dispositivo de control de accesos con reconocimiento del rostro y medición de la temperatura
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

EN
Connectors interfaces
J1
J2
J3
J4
J5
J6
J7
3 Installation
In case of temperature measurement, the device must be used in a preferably closed
environment at constant temperature. Do not install the device near hot/cold or ventilated
sources. Make sure that there are no heating/cooling sources within a 3 metre radius.
The accuracy of the temperature measurement will be affected when people enter the room from
a cold outdoor environment. The forehead temperature test must be performed after the
forehead has a stable temperature. It may take about three minutes to stabilise the temperature
if the ambient difference varies greatly.
The temperature read by the temperature measuring device is the temperature of the forehead.
When there is water on the forehead, sweat stains, oil stains, heavy make-up or wrinkles in the
elderly, the temperature read will be lower than the actual temperature, make sure the forehead
is free of hair or clothing.
Installation on access gate
According to the requirements of the installation site, it is necessary to open a hole with a
diameter of 35 mm on the turnstile, usually in the middle or in the front part, to install of the
access control/temperature measurement device (outer diameter of the hole of the supplied
bracket is 34 mm). The opening position of the hole is suggested in the following figure.
DS1099-066C
Access control systems
(output)
Reset
Power connector
Alarm output
Wiegand
RJ45
USB
Group 1 & 2 NO, default normally open,
Group 3 & 4 NC, default normally closed
12V DC
GND+ALMO alarm output 1, with no alarm the output
is at 3.3V, with alarm the output goes to 0V
-WGNI0 +WGNI1 (input). Currently not managed by
the software.
100Mbps
5V DM DP GND. Currently not managed by the
software.
12
Tabla de contenido
loading

Tabla de contenido