47855 CompuLevel

Use Tips

1) Secure the base unit before removing the measurement module
2) Extend the unipod from the top down and retract from the bottom up
(see page 12). Always tighten bushings (avoid over-tightening).
3) Hold the measurement module in the handgrip areas to the right and
beneath the keypad. For single handed operation, use the thumb to
press the most frequently used buttons: ON/OFF, HOLD and ZERO.
The left hand can manipulate the cord. Release or hold steady whilst
reading (see page 8).
4) In muddy conditions use a rag to wipe down the cord before reeling in.
This can also remove cord twists.
5) Always reel cord through cord entry area by holding the base unit
handle with base unit tilted backward at about 45° (for example,
resting against thigh). This will ease reeling, reduce wear and keep
docking area clean (see page 8).
6) Use a coin, screwdriver or thumbnail to loosen battery door screw to
replace 9V alkaline battery. Lift the terminal end of battery with
thumbnail or simply thump measurement module against your hand
and catch the battery. Note: The protective boot is more easily
removed when warmed.

How to Measure Accurately

COMPULEVEL
TM
less and 0.35% of measurements beyond 10ft. It can typically level to
within 1/8" over a single set-up.
1) For critical levelling frequently re-check or re-zero at the benchmark
(CAL is necessary for levelling). When possible minimise height
differences between cord, base unit and measurement module.
2) For critical elevation measurements, frequently re-check calibration
and benchmark zero. Whenever possible avoid temperature
difference between the cord and measurement module
(eg. sun vs. shade).
3) When moving the COMPULEVEL
different temperature, such as from indoors to outdoors on a cold day,
allow 10-15 minutes for COMPULEVEL
4) Avoid violent tugging, whipping or stomping on the cord without
re-check or re-zero at the benchmark.
5) Promptly zero or calibrate the COMPULEVEL
flashes –0-- or CAL.
6/11/07
11:14
is typically precise to within 0.2% of measurements 10ft or
Page 22
TM
from one temperature to a much
TM
to adapt to the change.
TM
when its display
Compulevel
TM
Measurement system • 22