Troubleshooting - FPZ SCL K07R Instrucciones

Compresores - aspiradores de canal lateral
Idiomas disponibles
  • ES

Idiomas disponibles

4.

TROUBLESHOOTING

Problem
The unit does not start
Air flow rate zero or
insufficient
Power absorption exceeds
the maximum allowed
Delivery air temperature
high
Excessive noise
Abnormal vibrations
Cause
The electric wiring is incorrect.
The power supply voltage is not suitable.
The impeller is stuck.
Rotation direction incorrect.
Intake filter clogged.
Wiring incorrect.
Voltage drop on the power supply.
Intake filter clogged.
Deposits have built up inside the unit.
The unit is operating at a pressure and/or vacuum
that exceeds that allowed.
The unit is operating at a pressure / vacuum that
exceeds that allowed.
Intake filter clogged.
Deposits have built up inside the unit.
Intake and/or delivery piping clogged.
Air temperature at intake exceeds 40°C.
The soundproofing fabric is damaged.
The impeller is scraping against the chassis:
a.
The unit is operating at a pressure / vacuum
that exceeds that allowed.
b.
The play allowed during assembly has been
reduced due to internal deposits (dust,
impurities in the pipes, process residue, etc.).
Bearing worn.
Installation position of the unit not suitable.
The impeller is damaged.
Deposits have built up on the impeller.
The unit is fixed incorrectly.
Solution
Check the electric wiring against the wiring diagram in
the terminal board box.
Check that the power supply voltage, measured at the
motor's terminals, is within ± 5% of the nominal
voltage.
Get trained personnel to repair the machine.
Check that the direction of rotation is as indicated on
the motor's fan cowling.
Clean or replace the cartridge.
Check the electric wiring against the wiring diagram in
the terminal board box.
Return the power supply voltage at the terminals to
within the values allowed.
Clean or replace the cartridge.
Get trained personnel to clean the machine internally.
Adjust the plant and/or the regulating valve to reduce
the pressure differentials.
Adjust the plant and/or the regulating valve to reduce
the pressure differentials.
Clean or replace the cartridge.
Get trained personnel to clean the machine internally.
Remove the obstructions.
Use a heat exchanger to reduce the air temperature
at the intake.
Replace the soundproofing fabric.
Adjust the plant to reduce the pressure differentials.
Get trained personnel to clean the machine internally.
Replace the bearing.
Install the units on structures that cannot transmit or
amplify the noise (tanks, steel plating, etc.).
Replace the impeller.
Get trained personnel to clean the machine internally.
Fix the unit on anti-vibration supports.
GB - 16/34