Water Supply Stops
INSTALLATION INSTRUCTIONS
Read All Instructions Carefully Before Beginning Installation.
CAUTION: FOR USE WITH WATER IN ACCESSIBLE LOCATIONS ONLY.
CAUTION: DO NOT SWEAT WITHIN 12 INCHES OF A G2 1/4 TURN VALVE.
CAUTION: FRACTURES CAN DEVELOP OVER TIME IF USED WITH CONNECTORS
USING A SOLID BRASS CONE DESIGN
Manufacturer assumes no responsibility for failure due to improper installation.
GENERAL INSTRUCTIONS:
instructions below:
COPPER COMPRESSION INLET
Be sure to shut off water before starting.
PEX COMPRESSION INLET
Be sure to shut off water before starting.
COMPRESSION NUT /
Tuerca de compresión
SLEEVE /
Manga
VALVE /
Llave de paso
COPPER TUBE /
Tubo de cobre
COMPRESSION NUT /
Tuerca de compresión
SLEEVE /
Manga
PEX TUBE
Tubo de PEX
VALVE /
Llave de paso
TUBE INSERT
/ Inserto para tubería
(IF NEEDED)
FEMALE IRON PIPE (FIP INLET)
Be sure to shut off water before starting.
Tools Needed for Installation:
SWEAT INLET
Be sure to shut off water before starting.
NOTE:
Tools Needed for Installation:
STEM ASSEMBLY /
Cartucho
FLUX
BONNET NUT
Pasta
Tuerca de capuchón
fundente
RUBBER BIBB WASHER
Arandela de goma
tipo babero
BRASS WASHER
Rondana de latón
CPVC INLET
Be sure to shut off water before starting.
CAUTION: USE ONLY CPVC CEMENT OR
AN ALL-PURPOSE CEMENT CONFORMING TO
ASTM F-493 OR JOINT FAILURE MAY RESULT.
CAUTION: ASSEMBLE VALVE ACCORDING
TO SOLVENT WELD MANUFACTURER'S
INSTRUCTIONS.
CAUTION: TOO MUCH CEMENT CAN CLOG WATERWAYS AND WEAKEN INSERT
IN FITTING OR VALVE.
Tools Needed for Installation:
THREAD SEALANT /
Selladora de rosca
PIPE NIPPLE
VALVE /
Llave de paso
Tubo roscado
ESCUTCHEN
Chapetón
SOLDER
Soldadura
STUB OUT
Caño de alimentación
SOLDER
Soldadura
VALVE SOCKET
Entrada de la llave de paso
CPVC PIPE
Tubo de CPVC