10. Troubleshooting
Doesn't work at all.
Are the batteries in the transmitter (13) and/or receiver (1)
worn out? Put in new batteries, if necessary.
The LCD (2) is dim.
Are the batteries in the receiver (1) worn out? Put in new
batteries, if necessary.
The red LED (17) on the transmitter doesn't light up.
Are the batteries in the transmitter (13) worn out? Put in
new batteries, if necessary.
The LCD (2) displays '- - -' as the current core
temperature (23).
Check whether the plug (15) for the temperature sensor
(14) is plugged into the jack (16) correctly. Plug the plug
in correctly.
The transmitter (13) and receiver (1) are too far apart.
Move them closer together, if necessary.
If necessary, turn off the transmitter (13) and receiver (1)
for three seconds and then turn them back on. That should
fix the problem
The LCD (2) blinks with red backlighting and
displays 'HI' and a warning signal sounds.
The maximum permissible temperature for the temperature
sensor (14) has been exceeded. Press the MEAT/STOP
button (7) to turn off the warning signal and end the
measurement.
11. Environmental information and
disposal
Disposal of Packaging
Sort the packaging prior to disposal. Dispose of
the packaging with the local utility company.
Disposal of Used Devices
Do not dispose of used devices together with
household waste! If at any time in the future
you should not use this device anymore, please
dispose of it in compliance with the applicable
regulations in your state or country. This ensures
professional recycling of used devices and
excludes negative consequences for the
environment.
Make sure that the disposal is in compliance
with
recommendations (www.epa.gov).
Questions?
Call customer service at 1 (844) 543-5872
Visit the Website Customer Service Platform at
www.lidl.com/contact-us
.
local
regulations
FLORABEST FFGT 433 A1
and
US-EN - 13
EPA