Inspection; Inspection Log - Guardian Halo Big Block SRL Manual De Instrucciones

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Inspection

Prior to EACH use, inspect Halo Series SRL for deficiencies, including, but not limited to, corrosion, deformation,
pits, burrs, rough surfaces, sharp edges, cracking, rust, paint buildup, excessive heating, alteration, broken
stitching, fraying, bird-caging, and missing or illegible labels. Inspect full length of lifeline. Pay careful
attention to cable swage (located beneath rubber stopper) and ensure no damage is present at location where
swage contacts lifeline. IMMEDIATELY remove Halo Series SRL from service if defects or damage are found.
Prior to EACH use, check lifeline retraction
by pulling out a minimum 4' and allowing
it to retract under light tension; lifeline
must retract completely. Pull lifeline
sharply to test braking function; brakes
must engage. Depending on model or
configuration, check shock pack for signs
of deployment, and/or fall arrest indicator
for signs of activation. Indicator will
display red if unsafe for use. See images
on right. Deployed indicator will also
allow swivel eye to lift up and away
from main body of hook as shown.
IMMEDIATELY remove from service if
Not Deployed
Deployed
Halo Series SRL does not function properly,
(OK for use)
(REMOVE FROM SERVICE)
or if exposed to forces of fall arrest.
Ensure that applicable work area is free of all damage, including, but not limited to, debris, rot, rust, decay,
cracking, and hazardous materials. Ensure that selected work area will support the application-specific
minimum loads set forth in this instruction manual. Work area MUST be stable.
Every 12 months, a Competent Person other than the user must inspect Halo Series SRL. Competent Person
inspections MUST be recorded in inspection log in instruction manual and on equipment inspection grid
label. The Competent Person must sign their initials in the box corresponding to the month and year
the inspection took place.
During inspection, consider all applications and hazards SRLs have been subjected to.

Inspection Log

Date of First Use: __________________.
Product lifetime is indefinite, as long as product
passes all inspection requirements. User must
inspect prior to EACH use. Competent Person other
than user must complete formal inspection at
least every 12 months. Competent Person to
inspect and initial.
This inspection log must be specific to one Halo
Series SRL. Separate inspection logs must be used
If equipment fails inspection
for each Halo Series SRL. All inspection records
IMMEDIATELY REMOVE FROM SERVICE.
must be made visible and available to all users
at all times.
5
Tabla de contenido
loading

Este manual también es adecuado para:

10917csa10918csa

Tabla de contenido