Chapin PRO Serie Manual De Uso Y Cuidado página 10

Ocultar thumbs Ver también para PRO Serie:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

TROUBLE SHOOTING YOUR SPRAYER
Symptom
Unit runs but does not spray
Unit will not start
Battery pack will not charge
Unit shuts off abruptly
Shut-off leaks
Wand assembly leaks
Nozzle assembly leaks
Leak between pump
assembly and tank
Hose leaking at tank outlet
Hose leaking at shut-off
Chapin Backpack Sprayer Operator's Manual - English
Possible Reason
Pump is not primed
Battery pack not installed properly
Battery pack not charged
Battery pack not inserted into charger
Charger not plugged in
Surrounding air temperature too hot or too cold
Battery pack has reached its maximum thermal
limit.
Out of charge. (To maximize the life of the battery
pack it is designed to shut off abruptly when the
charge is depleted.)
Connections loose
Worn or damaged shut-off
Connections loose
Damaged or worn o-ring/gasket
Connections loose
Damaged or worn o-ring/gasket
Pump clamp loose
O-ring worn or damaged
Hose clamp loose
Connection loose
Damaged or worn o-ring/gasket
9E
Correction
Activate shut-off handle until liquid
sprays out. Release handle and pump
will shut-off.
Check battery pack installation.
Check battery pack charging
requirements.
Insert battery pack into charger until
green LED appears.
Plug charger into a working outlet.
Refer to "Important Charging Notes"
for more details.
Move charger and battery pack to
asurrounding air temperature of above
40 degrees F (4.5ºC) or below 105
degrees F (+40.5º).
Allow battery pack to cool down.
Place on charger and allow to charge.
Tighten connection.
Rebuild or replace the shut-off valve.
Tighten connection.
Replace o-ring/gasket.
Tighten connection.
Replace o-ring/gasket.
Tighten clamp.
Replace pressure chamber o-ring.
Tighten clamp.
Tighten retaining nut.
Replace o-ring/gasket.
Tabla de contenido