Product Overview...................................................................... 2
About Your System.................................................................... 3
Safety Precautions:
WARNING: The installation of this system must be in accordance with all provincial/state and/or local laws and
regulations regarding plumbing and electrical services. Installation by a certified plumber is recommended.
Always comply with the following warnings and safety instructions, to prevent bodily harm, injury or property
damage.
DANGER: The lamp inside the unit emits ultraviolet light that can cause permanent damage to skin and eyes.
Never look at the lamps when unit is operating.
• Never attempt to operate your UV system unless it has first been properly grounded, to avoid creating an electric shock hazard.
• To prevent an electric shock, do not plug the UV system into any socket that has not been equipped with a Ground Fault Circuit
Interrupter (GFCI).
• Always unplug the power cord before attempting to install, clean or perform other routine maintenance on the unit.
• Always stop the inlet water flow before performing any maintenance on the unit.
• Do not attempt to service this unit unless you are an accredited service technician, as personal injury could result and/or
system operation could be detrimentally affected.
• Never operate this unit in an oxygen-rich environment, or within 6 feet (2 meters) of any oxygen source.
• If temperatures should fall below freezing (0°C / 32°F), drain all water from the unit, drain and disconnect all plumbing lines,
and cap the inlet and outlet ports.
• Do not attempt to install, operate, clean or perform routine maintenance on your UV system unless you have first read and
understand all of the warnings and safety instructions that are contained in this manual and on the labels that are affixed to
the system.
• Do not attempt to operate the UV system if it has been visibly damaged. Inspect it carefully to ensure it is free of
physical damage before using.
• Do not operate if the system is wet or if there are visible leaks.
• The UV system is electrically certified for indoor applications only and should not be exposed to outdoor elements.
• Always install and operate the unit in an environment where both the air and water temperatures will normally range between
36°F (2°C) and 104°F (40°C).
This Class B system or component conforms to NSF/ANSI Standard 55 and CSA B483.1 for the supplemental bactericidal treatment
of disinfected public drinking water or other drinking water that has been tested and deemed acceptable for human consumption
by the state or local health agency having jurisdiction. The system is only designed to reduce normally occurring non-pathogenic
nuisance microorganisms. Class B systems are not intended for treatment of contaminated water.