• Motor load: 2A at 250 Vac
• Power factor correction in fluorescent load: 1A at 250 Vac
• Ferromagnetic transformer load: 1A at 250 Vac
• Electronic transformer load: 1A at 250 Vac
Note: the sum of the currents for all the loads (terminal C) must be 10A maximum.
• Controls:
- Lightly touching the sensitive zones, identified by the blue LED on the device's front panel with your finger.
- From various other points using the touch buttons for remote control (cod. 442TC05S) or non-luminous NO
buttons connected to the phase.
• Status memory: the device's channels programmed using a bistable function have a status memory that
ensures that the status of the output relay is saved, if the power supply is interrupted.
• LED Indicators:
- Six blue optical indicators can be seen on the front, which are always lit at minimum level to allow them to
be found in the dark. When a touch is sensed, the LED emits a stronger light.
• Sound Indicator:
- An acoustic confirmation signal is provided, which is useful during programming.
• Electrical duration:
- 100,000 manoeuvres at Maximum resistance and inductive load at 250 Vac, and at maximum switching
frequency of 1000 cycles per hour.
• Possibility of setting output functioning mode: monostable, timed monostable, bistable, and interlocked, for
both timed and "man in attendance" mode (see PROGRAMMING paragraph)