ENGLISH
Function
Capacitance
Maximum Input: 750V AC RMS or 600V DC
Temperature
°F
Temperature
°C
Maximum Input: 750V AC RMS or 600V DC
Frequency
Duty Cycle
Maximum Input: 750V AC RMS or 600V DC
OTHER MEASUREMENT APPLICATIONS
Maximum Input: 600V DC or 750V AC RMS
• Diode Test: Approx. 1mA, open circuit voltage ~3.0V DC
• Continuity Check: Audible signal <10Ω, max current 1.5mA
• Sampling Frequency: 3 samples per second
• Overload: "OL" indicated on display
• Polarity: "-" on display indicates negative polarity
• Display: 3-5/6 digit, 6000 Count LCD
4
ELECTRICAL SPECIFICATIONS
Range
60.00nF
600.0nF
6.000 F
60.00 F
600.0 F
6.000mF
-328° to 54°F
55° to 2462°F
-200° to 12°C
13° to 1350°C
10Hz to
60kHz
0.1% to 99.9%
(≤10kHz)
Resolution
0.010nF
0.100nF
0.001 F
0.010 F
0.100 F
0.001mF
1°F
1°C
0.001Hz
to 0.01kHz
0.1%
(Range: 10% – 90%)
Accuracy
±(4% + 25 digits)
±(4% + 8 digits)
±(5% + 9 digits)
±(1.5% + 7 digits)
±(1.2% + 6 digits)
±(1.5% + 4 digits)
±(1.2% + 3 digits)
±(0.1% + 5 digits)
±1.5%