- Pipe-work shall be protected from physical damage and shall not be installed in an unventilated space,
if that space is smaller than 8 m².
- Compliance with national gas regulations shall be observed.
- Keep any required ventilation openings clear of obstruction.
- The appliance shall be stored in a well-ventilated area where the room size corresponds to the room
area as specifi ed for operation.
Warning
- Failure to abide by this warning could result in an explosion, death, injury and property damage.
- Any person who is involved with working on or breaking into a refrigerant circuit should hold a current
valid certifi cate from an industry-accredited assessment authority, which authorizes their competence
to handle refrigerants safely in accordance with an industry, recognized assessment specifi cation.
- Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance
and repair requiring the assistance of other skilled personnel shall be carried out under the supervision
of the person competent in the use of fl ammable refrigerants.
Recycle unwanted materials instead of disposing of them. All appliances and packaging should
be sorted and tendered at a regional recycling centre and be processed in an ecological manner
This unit uses a fl ammable refrigerant.
If refrigerant leaks and comes in contact with fi re or heating part, it will create harmful gas and
there is risk of fi re.