Cartridge Assembly - Horton Polar-Extreme S Instrucciones De Servicio

Para los embragues de ventilador tipo s y ht/s
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

11. Remove the O-ring from the Piston Friction Disc
and clean the O-ring contact surfaces.
12. Lubricate the new D (O)-ring and D (O)-ring
contact surfaces with the fresh lubricant
supplied in the kit; then, install the new D (O)-
ring onto the Piston Friction Disc.
The entire tube of the lubricant should be used
when lubricating the new D (O)-rings and D (O)-
ring contact surfaces. Extra lubricant may be
placed in the bottom of the Air Chamber. A slight
amount of lubricant will be needed for the O-rings
on the Cartridge Assembly.
Wear safe eye protection when removing
Retaining Rings to prevent serious eye injury.
1.
Remove the Retaining Ring.
2.
Remove the Cartridge Assembly and, if
applicable, the U-cup. Clean the Journal
Bracket bore if necessary.
The Cartridge Assembly shown in Step 2 is an
older style brass Cartridge. The new Cartridge
Assembly does not use the U-cup Seal. Make
sure you DISCARD the U-cup Seal upon
installation of this new style Cartridge.