RS-232 Commands

The LISN interprets the following remote control
commands.
Please consider the lower/upper case letters.
Com-
mand Function
R
Remote control enabled
O
Local control
P
Protect. ground line
sim. circuit on
p
Protect. ground line
sim. circuit off (bypass)
N
EMC test signal of line N
n
EMC test signal of line L1 L1 LED lit
L
Transient Limiter off
l
Transient Limiter activated OFF LED
Indication
RM LED lit
RM LED
dark
PE LED lit
PE LED dark
N LED lit
OFF LED
blinking
dark