3.2 DIL switch setting
The settings of the DIL switches for configuring the pneu-
matics (number of valve solenoid coils used) can be made
on the fitted CPX terminal.
1. Remove the screws and lift up the cover.
2. Set the DIL switches in accordance with the valve con-
figuration (see following table).
3. Check the seal and sealing surfaces and refit the cover.
4. Tighten the screws by hand in diagonally opposite
sequence:
S CPX-GP-03-4.0: Tightening torque 1.0...1.3 Nm.
S CPX-GP-CPA-..: Place the screws so that the self-
cutting threads are used. Tightening torque
0.9...1.1 Nm.
Festo CPX-GP-... 0201NH English
15