9.5 – SETTINGS menu - Programming of specific control panel functions
The various menu options are visible be scrolling with the arrows after having confirmed the main screen.
Certain control panel operating and control parameters are defined in this section as shown below.
In order to access the options and enter/change programmes, the same keys are used and the same procedures are followed as in the previous
operations.
a) Sensor/detector exclusion: in the SETTINGS menu find EXCL. SENSORS and confirm.
Then find the detector to be excluded (↑ ↓) , confirm with ↵ and change INCLUD (activated) to
EXCLUD (deactivated) by using the arrows. Confirm with ↵ and exit with ESC.
b) Wired inputs exclusion – this operation can also be performed by the user by accessing the menu
EXCL. WIRED INP. and proceeding as above. In both cases a) and b) the excluded detectors will not start an alarm.
c) RELAY1 SETTINGS: Factory ON-OFF setting (bistable switch), switches after ON command and stops with OFF command of the internal
clock or via telephone. Switching via telephone predominates over the clock command.
The various settings (↑ ↓) allows the use of relay R1 for other purposes as follows:
IMPULSIVE
GENERAL ALARM
TAMPERING AL.
24H PANIC/ROBBERY/TECHNOL.
ANOMALY
ARM./DISARM.
Once the desired function is found, modify times if necessary and confirm ↵
Note: In order for R1 to be controlled by the internal clock (see 4.7), it must be set on ON-OFF or IMPULSIVE.
d) RELAY2 SETTINGS: The factory setting is GENERAL ALARM, timed at 3 minutes. If this setting needs to be changed, proceed as indicated
above, selecting a different function.
9.6 – Functions enabling The functions described below are not listed in the sequence as they appear in the menu, but all of them must be
enabled with (↑ ↓) in order to be operative and for the Y (yes) to appear on the display rather than the N (no), and confirmed in the desired
conditions.
a) MAINS FAILURE: the number of minutes (01-99) to elapse before a signal is generated must be entered (in models with a GSM module this
occurs via SMS) Regardless of the time entered, the words MAINS FAILURE appear flashing on the display.
b) PERIODIC CALL: enter the starting time and then the number of hours (1-999) to elapse before an SMS operating status of the control panel
is sent.
c) SIM VALIDITY: enter the expiry date of the SIM card by using the numbers on the keypad.
d) ANTISCANNER: the control panel checks the radio signals in the ether and those which interfere with its functioning. The time in seconds (1-
60) for negligible interferences can be set, after which the control panel will set off the alarm siren and terminal SIR will be powered for 30
seconds.
e) SUPERVISION: supervision is the transmission of the operating status which every peripheral device transmits approx. every 20 minutes.
The absence of 8 consecutive signals (over 3 hours) from a peripheral device causes a signal to this effect to be generated with every
arming/disarming of the system.
f) AUT.SUMMER H: daylight-saving time is activated by default. To be deactivated in countries where this does not apply.
g) BACKLIGHTING: it is possible to maintain the display permanently back-lit. Normally the back-lighting switches off after 60 seconds.
h) FORCED ARMING: It is possible to set time and zone for daily automatic arming of the control panel.
9.7 – Other SETTINGS functions
a) GSM-PSTN line (only with GSM): select one of the two systems as default for calls (↑↓)
b) TIME AND DATE: update time and date which are essential for timely operations and are stored in the events memory.
c) TEL. EXCHANGE: if the control panel is connected to the telephone line after an exchange, it is possible to enter the external number access
without having to repeat it in the programming of the telephone numbers. For security reasons it is advisable to always connect the control panel
before any exchanges.
d) USER CODE / INSTALLER CODE: the functions allow the codes to be changes.
Note: It is the customer's legal right to know all the access codes of the owned device. Changes to codes are stored in the events memory. If
the codes are not known, the main power supply to the control panel must be disconnected and the menu with the factory code 0000 accessed.
e) EXIT TIME (written SET ENTRY DELAY): this time is set at the factory at 60 seconds and ensures that the control panel becomes activated
after this set period. The time can be changed by entering a number from 00 to 99. Note: Times which are too short do not allow the display of
doors/windows left open which appears on the control panel during the exit time (example, DOOR OPEN 01) and is locally communicated
(events recording).
RIPETIZIONE, GIA' PRIMA!! f) Automatic daylight-saving time: This function is normally enabled but must be disabled in countries where it
does not apply.
f) FW VERSION: it displays the firmware version in order to allow possible technical service.
g) SYSTEM RESET: confirmation of DELETE? results in the total erasing of all the programming performed and of the events memory. Be
careful before confirming this operation which is irreversible.
Note: Erasing the events memory following a negative event (theft/intrusion) may result in penalties for the person having performed this
operation.
SILENTRON – made in Italy
Switches for a programmed time from 0 to 999 seconds following a telephone or internal clock command.
Switches for the time programmed when the control panel is in a state of alarm of any kind excluding anti-scanner.
Switches for 3 minutes in the case of a tamper alarm.
Switches for 15 minutes in the case of a panic/robber/ technical alarm.
Switches for 15 seconds in the case that the battery is low (control panel and/or detectors), failed
supervision,radio interference with system armed (anti-scanner), no GSM field in models with module.
Switches during arming and stops upon disarming (useful for connecting an indicator light to show the status of
the control panel).