Disconnect power before working on
pump, motor, pressure switch or wiring
Motor may be hot. Allow to cool 20
!
minutes.
Water pressure may have built up in
!
the pump, pipes and/or tank. Drain
water to relieve pressure.
Motor Switch Settings
Motors are designed to run on either 115 volt or 230 volt
current. Be sure the motor's current is set to match the
current being supplied to your motor from the electrical
source.
To set your motor to the correct voltage, first remove the
rear cover plate. Next slide the voltage conversion switch
to the correct voltage. WIRING THE PUMP FOR THE
INCORRECT VOLTAGE WILL DAMAGE THE PUMP.
Wiring Connections
Risk of electric shock. Electricity
can shock, burn or kill.
1. To avoid dangerous or fatal electrical shock, turn OFF
power to motor before working on electrical
connections.
2. Ground motor before connecting to electrical power
supply. Failure to ground motor can cause severe or
fatal electrical shock hazard.
3. Supply voltage must be within +/- 10% of nameplate
voltage. Incorrect voltage can cause fire or damage
motor and voids warranty. If in doubt consult a
licensed electrician.
Wiring Chart Recommended Wire and Fuse Sizes for 115 and 230 volts
MOTOR HP
VOLTS
1
115/230
1-1/2
115/230
2
115/230
For parts or assistance, call ECO-FLO Customer Service at 1-877 326-3561
For parts or assistance, call ECO-FLO Customer Service at 1-877 326-3561
ELECTRICAL
BRANCH
MAX. LOAD
FUSE
AMP
RATING AMP
18.5/9.25
30/15
22/11
30/15
27/13.5
30/20
4. Use wire size specified in Wiring Chart (below). If
possible, connect pump to a separate branch circuit
with no other appliances on it.
5. Do not ground to a gas supply line.
6. Wire motor according to diagram on motor nameplate.
If nameplate diagram differs from diagrams above,
follow nameplate diagram.
7. If this procedure or the wiring diagrams are
confusing, consult a licensed electrician.
DISTANCE IN FEET FROM MOTOR TO SUPPLY
0-100
101-200
AWG WIRE SIZE (mm
10/14 (6/2.5)
8/14 (10/2.5)
10/14 (6/2.5)
8/14 (10/2.5)
10/12 (6/4)
8/12 (10/4)
6
201-300
301-400
2
)
6/12 (16/4)
4/10 (25/6)
4/10 (25/6)
6/12 (16/4)
4/10 (25/6)
4/10 (25/6)
6/10 (16/6)
4/8 (25/10)
4/8 (25/10)
401-500